{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"DT50-P2113","brand":"SICK","brandSlug":"sick","productSlug":"DT50-P2113","canonicalUrl":"https://aoctrl.com/sick/DT50-P2113","factsUrl":"https://aoctrl.com/api/mcp/products/DT50-P2113","rawCanonicalId":null},"summary":{"shortDescription":"SICK Dx50 series, DT50-P2113 optical distance sensor, 20 m sensing range, red laser, PNP output, 15 ms response, IP65, M12 5-pin connector.","salesMarkdown":"## What the 20 m laser range means for your application The SICK DT50-P2113 is a Dx50 series optical distance sensor that delivers a 20 m sensing range using a red laser light source. That 20 m reach means it can resolve position on a moving target — a crane trolley, an AGV, a gantry axis — without needing a separate reflector or target plate. The laser spot stays collimated over the full range, so the measurement is repeatable within the sensor's resolution at both 200 mm minimum and 20 m maximum. Response time is 15 ms. ## PNP output and connector — wiring considerations The DT50-P2113 terminates in an M12, 5-pin male connector and provides a PNP switching output. Operating voltage range is 10 to 30 VDC.","metaTitle":"SICK DT50-P2113 Dx50 Distance Sensor, 20 m Red Laser, PNP","metaDescription":"SICK DT50-P2113 Dx50 optical distance sensor. 20 m range, red laser, PNP output, 15 ms response, IP65, M12 connector. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Proximity Sensors"],"specifications":{"Width":"36 mm","Height":"63 mm","Length":"58 mm","Series":"Dx50","Light Type":"Red Laser","Sensor Type":"Distance Sensor","Response Time":"15 ms","lifecycle_stage":"current","Termination Type":"Connector, M12, 5-Pin, Male","Protection Rating":"IP65","Sensing Distance Max.":"20 m","Sensing Distance Min.":"200 mm","Operating Voltage Max.":"30 VDC","Operating Voltage Min.":"10 VDC","Operating Temperature Max.":"140 °C","Operating Temperature Min.":"-30 °C","Optical Sensor Output Type":"PNP"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f2ad1da381dd51291ccf7ebc6bf433b9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/DT50-P2113/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to the DT50-P2113?","answer":"The closest functional sibling is the DT50-P1123, which shares the same form factor, connector, output type, and IP rating but is limited to a 10 m sensing range and has a 20 ms response time."},{"question":"Will the DT50-P2113 drop into a panel designed for the DT50-P1123 without rewiring?","answer":"Yes. Both sensors share the same 36 mm x 63 mm x 58 mm housing, the same M12 5-pin male connector, and the same PNP output type. The mounting holes and connector location are identical, so it is a direct mechanical and electrical replacement."},{"question":"What compliance documentation is available for the DT50-P2113?","answer":"The manufacturer provides standard compliance documentation including a datasheet with specifications. For specific certifications (RoHS, REACH, UL, IEC), request the current declaration of conformity from your distributor with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/sick/DT50-P2113","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/sick/DT50-P2113 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}