{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"DVP02LC-SL","brand":"Delta","brandSlug":"delta","productSlug":"DVP02LC-SL","canonicalUrl":"https://aoctrl.com/delta/DVP02LC-SL","factsUrl":"https://aoctrl.com/api/mcp/products/DVP02LC-SL","rawCanonicalId":null},"summary":{"shortDescription":"Delta DVP02LC-SL load cell measurement module, 20-bit resolution, 0 ~ 6mV/V input range, current lifecycle stage.","salesMarkdown":"## What this module does The DVP02LC-SL is a dedicated load cell signal-conditioning module for Delta's DVP series PLCs. It accepts strain-gauge bridge inputs across a 0 ~ 6mV/V range and resolves them at 20-bit — that is the internal conversion resolution, not an effective-number-of-bits figure, so the usable precision depends on the sensor's excitation voltage and the electrical noise floor in the cabinet. The measurable range of 0 ~ 6mV/V matches the full-scale output of most common industrial load cells at 5 V or 10 V excitation. If your cell outputs 2 mV/V at rated load, you will use roughly the lower third of the ADC range — still within the module's linear region, but you lose some resolution compared to a cell that fills the full span.","metaTitle":"DVP02LC-SL Delta Load Cell Module, 20-bit, 0~6mV/V","metaDescription":"DVP02LC-SL load cell measurement module from Delta. 20-bit resolution, 0~6mV/V input range. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Resolution":"20-bit","Manufacturer":"DELTA","Shipping Weight":"2 Kg","lifecycle_stage":"current","Measurable range":"0 ~ 6mV/V","Estimated Lead Time":"Usually ships in 1 - 10 working days."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$357.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/DVP02LC-SL/alternatives.json"},"ai":{"faq":[{"question":"What is the resolution on this module?","answer":"The DVP02LC-SL has a 20-bit internal conversion resolution on a 0 ~ 6mV/V measurable input range. That is the ADC resolution, not effective-number-of-bits; real usable precision depends on the load cell's output and installation noise."},{"question":"How does the DVP02LC-SL compare to the DVP01LC-SL?","answer":"Both modules share the same 20-bit resolution and 0 ~ 6mV/V measurable range, and both weigh 2 Kg shipped. The DVP01LC-SL is the earlier variant; functionally they are interchangeable for the same load cell input spec. If your panel was wired for a DVP01LC-SL, the DVP02LC-SL drops in without rewiring — same backplane bus, same terminal assignments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/delta/DVP02LC-SL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/DVP02LC-SL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}