{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"DVP60ES200R","brand":"Delta","brandSlug":"delta","productSlug":"DVP60ES200R","canonicalUrl":"https://aoctrl.com/delta/DVP60ES200R","factsUrl":"https://aoctrl.com/api/mcp/products/DVP60ES200R","rawCanonicalId":null},"summary":{"shortDescription":"Delta DVP Series PLC, DVP60ES200R, 36 inputs, 24 relay outputs, 100-240 VAC.","salesMarkdown":"## What this PLC brings to a control panel The Delta DVP60ES200R is a 60-I/O programmable logic controller from the DVP Series, built for medium-scale discrete and process control. It carries 36 inputs and 24 relay outputs, powered from a universal 100-240 VAC supply. The relay outputs handle up to 2 A per point typically, switching motor starters, contactors, solenoids, and indicator loads directly without external interposing relays — a common need on a pulp-and-paper wet-end or finishing line where you want to keep the cabinet simple and the machine running. The 36-input count suits applications like a multi-stage conveyor system, a batch reactor with discrete level and valve feedback, or a paper-machine section with dozens of proximity and limit switches. The 24 relay outputs give you the current-carrying capacity to drive the loads directly, which saves panel space and wiring time compared to adding interface relays for every output. ## Relay vs. transistor output — the real decision The DVP60ES200R uses relay outputs, while its sibling DVP60ES200T uses transistor (sink/source) outputs. The relay version is the right call when you need to switch mixed AC/DC loads, high inrush currents, or voltages above 24 VDC — typical for driving motor contactors, hydraulic valve coils, or heater contactors in a mill environment. The transistor version is faster (no mechanical wear, higher switching frequency) but limited to 24 VDC low-current loads. If your application is all 24 VDC sensors and small solenoid valves, the DVP60ES200T may be a better fit; if you have any 120 VAC or 24 VDC loads above 0.5 A, the relay version is the practical choice. The DVP60ES200R mounts on a DIN rail in the control cabinet. The 60-I/O density fits a medium-sized panel; plan for at least 300 mm of DIN rail width plus clearance for wiring ducts. The relay outputs use common terminals — wire the commons per load group (same phase/voltage) to keep the wiring tidy. Inputs are typically 24 VDC sink/source; verify your sensor type before terminating.","metaTitle":"Delta DVP60ES200R PLC, 36 Inputs 24 Relay Outputs, 100-240 V","metaDescription":"Delta DVP60ES200R PLC with 36 inputs and 24 relay outputs, 100-240 VAC supply. Current production. Relay outputs switch motor starters and solenoids directly. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Inputs":"36","Outputs":"24","Product No.":"DVP60ES200R","Manufacturer":"DELTA","Power Supply":"100 ~ 240 V","Product Type":"Programmable Logic Controller DVP Series","Output Method":"Relay","Shipping Weight":"2 Kg","lifecycle_stage":"current","Estimated Lead Time":"Usually ships in 1 - 10 working days."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$364.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/386fdc8b1ea08acede98971614ea3d28.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/DVP60ES200R/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between DVP60ES200R and DVP60ES200T?","answer":"The DVP60ES200R uses relay outputs (good for mixed AC/DC loads, higher current, and inductive loads like contactors). The DVP60ES200T uses transistor outputs (faster switching, but limited to 24 VDC low-current loads). Both have the same 36 inputs and 24 output count, same power supply, and same form factor. Choose relay for motor starters and solenoids; choose transistor for high-speed DC loads."},{"question":"What are the key specifications of the DVP60ES200R?","answer":"The DVP60ES200R has 36 inputs, 24 relay outputs, and operates on 100-240 VAC power. It is part of the Delta DVP Series of programmable logic controllers."},{"question":"Can the DVP60ES200R replace a DVP60ES200T in an existing panel?","answer":"Mechanically and electrically they are the same footprint and use the same power supply, so the DVP60ES200R will mount and wire into the same panel. However, the output wiring differs: relay outputs (R) are dry contacts, while transistor outputs (T) are solid-state with a common DC supply. You must re-terminate the output field wiring and verify load compatibility — relay outputs can switch AC or DC, but transistor outputs require 24 VDC loads only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/delta/DVP60ES200R","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/DVP60ES200R when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}