{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"E2E-X5Y1 5M","brand":"Omron","brandSlug":"omron","productSlug":"E2E-X5Y1-5M","canonicalUrl":"https://aoctrl.com/omron/E2E-X5Y1-5M","factsUrl":"https://aoctrl.com/api/mcp/products/E2E-X5Y1%205M","rawCanonicalId":null},"summary":{"shortDescription":"Omron E2E-X5Y1 5M, M18 shielded inductive proximity sensor, AC 2-wire, NO output, 5 mm sensing distance, 2 m pre-wired cable.","salesMarkdown":"The Omron E2E-X5Y1 5M is a shielded M18 cylindrical inductive proximity sensor, AC 2-wire normally-open output, rated for 24 to 240 VAC (operating range 20 to 264 VAC). It detects ferrous metal at 5 mm ±10%, with a recommended setting distance of 0 to 4 mm. The pre-wired 2 m cable and IP67 / oil‑proof enclosure make it a direct drop for panels that require flush mounting in metal and resistance to cutting fluids or washdown. The nearest functional sibling is the E2E-X5MY1 2M (also AC 2‑wire, NO, 5 mm sensing). The critical difference: the X5Y1 is shielded (M18 head), while the X5MY1 is unshielded (M12 head). Shielded permits flush mounting in metal without derating the sensing distance; unshielded requires a non‑metal zone around the head. Also, the X5Y1 switches 5–300 mA, the X5MY1 only 5–200 mA. If your BOM uses an M18 threaded hole and needs flush mounting, the X5Y1 is the correct fit — the X5MY1 requires a 12 mm hole and non‑flush conditions. Listed as current production — no end‑of‑life notice. Sourced to order; send an RFQ with your volume and delivery window for a firm lead time.","metaTitle":"Omron E2E-X5Y1 5M Proximity Sensor, M18 Shielded AC 2-Wire,","metaDescription":"Omron E2E-X5Y1 5M inductive proximity sensor, M18 shielded, AC 2-wire, 5mm sensing distance, 24-240VAC, IP67, 2m cable. Active production — source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Proximity Sensors"],"specifications":{"Ype":"Cylinder type (with screw), Shielded","title":"E2E-X5Y1 5M","Weight":"Package: Approx. 130 g","Material":"Case: Brass nickel platingSensing surface: Polybutylene terephthalate (PBT)Clamping nuts: Brass nickel platingToothed washers: Iron zinc plating","Indicator":"Operation indicator (red)","Accessories":"Instruction manual","description":"AC 2-wire/Pre-wired Models * SAME DAY DELIVERY - 1 UNIT ONLY*","Power source":"AC 2-wire models","Operation mode":"NO","Sensing object":"Ferrous metal (Sensitivity lowers with non-ferrous metals.)","Leakage current":"1.7 mA max.","Shipping Weight":"1.5 Kg","lifecycle_stage":"current","Sensing distance":"5 mm ±10%","Setting distance":"0 to 4 mm","Shock resistance":"Destruction: 1000 m/s<sup>2</sup> 10 times each in X, Y, and Z directions","Connection method":"Pre-wired models (2 m)","Sensing head size":"M18","Voltage influence":"±1% max. of sensing distance at rated voltage in the rated voltage ±15% range","Protective circuit":"Surge suppressor","Response frequency":"25 Hz","Dielectric strength":"Between charged parts and the case: 4,000 VAC 50/60 Hz 1 min","Degree of protection":"IEC: IP67Company standard: Oil-proof","Emperature Influence":"±10% max. of sensing distance at 23 ? in the temperature range of -25 to 70 ?±15% max. of sensing distance at 23 ? in the temperature range of -40 to 85 ?","Power supply voltage":"24 to 240 VAC","Vibration resistance":"Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h","Differential distance":"10% max. of sensing distance","Insulation resistance":"Between charged parts and the case: 5 MΩ min. at 500 VDC","Operating voltage range":"20 to 264 VAC","Standard sensing object":"Iron 18 x 18 x 1 mm","Ambient humidity (Storage)":"35 to 95% RH","Ambient humidity (Operating)":"35 to 95% RH","Ambient temperature (Storage)":"-40 to 85 ?","Ambient temperature (Operating)":"-40 to 85 ?","Control output (Switching capacity)":"5 to 300 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$63.50 – $85.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1556f612f724bdf25fa2360ca1930b7c.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the closest functional alternative if the E2E-X5Y1 5M is not available?","answer":"The E2E-X5MY1 2M is the nearest second‑source: same AC 2‑wire, NO, 5 mm sensing, but it is unshielded with an M12 head and switches 5–200 mA instead of 5–300 mA. Check your mounting hole size and flush‑mount requirement before substituting."},{"question":"What is the sensing head size and type of the E2E-X5Y1 5M?","answer":"It is a shielded M18 cylinder type (with screw)."},{"question":"Will the E2E-X5Y1 5M drop into a panel specified for the E2E-X5MY1 2M without rewiring?","answer":"No — the E2E-X5Y1 5M has an M18 thread, while the E2E-X5MY1 2M uses an M12 thread. The electrical connections are the same 2‑wire AC, but the mounting hole size is different. A panel drilled for M12 cannot accept an M18 sensor without modification."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/E2E-X5Y1-5M","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/E2E-X5Y1-5M when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}