{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"E2EX4MB1TL82MOMS","brand":"Omron","brandSlug":"omron","productSlug":"E2EX4MB1TL82MOMS","canonicalUrl":"https://aoctrl.com/omron/E2EX4MB1TL82MOMS","factsUrl":"https://aoctrl.com/api/mcp/products/E2EX4MB1TL82MOMS","rawCanonicalId":null},"summary":{"shortDescription":"Omron E2E-Next M8 inductive sensor, PNP NO, 4 mm sensing distance, non-flush mount, 2 m cable, stainless steel, IP69K, operating -40 to +85°C.","salesMarkdown":"## Sourcing & Fit E2EX4MB1TL82MOMS is an active-production E2E-Next M8 inductive proximity sensor — non-flush, 4 mm sensing range, PNP normally-open output, with a 2 m cable termination. Current lifecycle stage means you can quote it into a BOM line without worrying about a last-time-buy window. Runs on 10–30 VDC, draws 16 mA quiescent, and switches 200 mA loads up to 1 kHz. The stainless steel housing holds IP67, IP67G (with gasket) and IP69K — that top rating covers high-pressure, high-temperature washdown cycles common in food or pharmaceutical lines. Length 47.8 mm — slightly longer than some M8 cans, so check the bracket depth if you're swapping into a tight existing mount point. ## How It Differs from the E2B Flush-Mount Sibling The common cross-shop candidate is E2BS08KS02MCB120OMS — an E2B-series M8, but it's flush-mount with 2 mm sensing, a narrower temperature window (-25 to +70 °C), and only IP67. The E2E-Next here is non-flush (so you need more standoff from steel), offers twice the sensing distance (4 mm), reaches down to -40 °C and up to +85 °C, and adds IP69K. If your current panel was wired for a flush-mount sensor and uses the metal face as the target, the non-flush of this one won't work without adjusting the bracket. But if the installation already provides that clearance, you get better reach and washdown resilience. ## Lifecycle & Supply Designated as current production — no PCN or phase-out signal. The E2E-Next series is Omron's standard mid-range inductive line, and this variant is widely specified. Lead time depends on volume; we can quote firm dates against an RFQ. ## Mounting & Wiring Notes Non-flush mount: keep a shielded zone around the face per the datasheet's recommended standoff — typically about twice the sensing distance (8 mm free metal). The 2 m PVC cable comes with bare flying leads; strip and terminate to a screw clamp or M8 pigtail if you need a quick-disconnect on the panel door. Operating range covers -40 to +85 °C, so it lives in cold storage aisles or near ovens without derating. PNP NO output sinks to ground when the target is present — watch the load current stays under 200 mA continuous; the sensor itself only draws 16 mA from the supply.","metaTitle":"Omron E2EX4MB1TL82MOMS Inductive Sensor, M8, 4mm, PNP NO","metaDescription":"Omron E2E-Next M8 inductive sensor, non-flush, 4mm sensing distance, PNP NO, cable 2m, IP67/IP69K, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Proximity Sensors"],"specifications":{"title":"E2EX4MB1TL82MOMS","Length":"47.8 mm","Series":"E2E-Next","description":"Inductive Sensor PNP, NO 1kHz 30V 16mA 4mm Cable, 2 m IP67 / IP67G / IP69K E2E-Next","Load Current":"200 mA","Mounting Type":"Non Flush Mount","lifecycle_stage":"current","Housing Material":"Stainless Steel","Termination Type":"Cable, 2 m","Construction Form":"M8","Protection Rating":"IP67;IP67G;IP69K","Current Consumption":"16 mA","Switching Frequency":"1 kHz","Sensing Distance Max.":"4 mm","Operating Voltage Max.":"30 V","Operating Voltage Min.":"10 V","Operating Temperature Max.":"85 °C","Operating Temperature Min.":"-40 °C","Inductive Sensor Output Type":"PNP, NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$64.21","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50fb63c54bd090ef5e85ef09d264627a.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is this sensor's length?","answer":"47.8 mm long, measured including the threaded body but not the cable exit."},{"question":"What series does E2EX4MB1TL82MOMS belong to?","answer":"Omron E2E-Next."},{"question":"Will E2EX4MB1TL82MOMS drop into a panel designed for E2BS08KS02MCB120OMS?","answer":"Not directly. The E2B sensor is flush-mount (2 mm sensing) while this E2E-Next is non-flush (4 mm). The M8 diameter is the same, but the mounting requirement differs — you'll need to allow extra clearance for the non-flush face. Also the cable termination vs M8 connector means different wiring path. It's a functional upgrade only if the installation can accommodate the standoff."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/E2EX4MB1TL82MOMS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/E2EX4MB1TL82MOMS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}