{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"E5CC-RX2ASM-006","brand":"Omron","brandSlug":"omron","productSlug":"E5CC-RX2ASM-006","canonicalUrl":"https://aoctrl.com/omron/E5CC-RX2ASM-006","factsUrl":"https://aoctrl.com/api/mcp/products/E5CC-RX2ASM-006","rawCanonicalId":null},"summary":{"shortDescription":"Omron E5CC-RX2ASM-006 digital temperature controller, 48x48 mm 1/16 DIN panel cutout, universal input (thermocouple, RTD, analog), relay control output, 100-240 VAC supply, screw terminals, two event inputs and transfer output.","salesMarkdown":"## 48x48 mm panel fit and what the relay output means for the loop The E5CC-RX2ASM-006: The 48x48 mm face (1/16 DIN standard) fits the common panel cutout — no adapter plate needed for a standard enclosure punch. Control output 1 is a relay (rated for general-purpose switching), not a solid-state or linear DC drive. That means the output cycles an external contactor or SSR — it does not drive a heater directly beyond a few amps. Control output 2 is omitted (X = None), so this variant is a single-loop controller with no second analogue or relay output for dual-actuator or cascade schemes. ## Universal input and auxiliary I/O — one SKU covers multiple sensor types The universal input (M type) accepts thermocouple (J, K, T, etc.), RTD (Pt100), or analogue signals (0-10 V, 4-20 mA) without a separate input module — the sensor type is set in software during commissioning. Two auxiliary outputs are available for alarms, event signalling, or retransmission — useful for driving a remote indicator or triggering a safety shutdown on a process deviation. The 006 option adds two event inputs and a transfer output, giving the controller the ability to switch between preset sets or latch a remote reset signal without an external PLC. ## Power supply and wiring — global voltage, field-friendly terminals Rated for 100 to 240 VAC, the controller powers up on any standard line voltage from 100 V Japanese to 240 V European without a voltage selector jumper — one part number covers global installs. Screw terminals (S type) accept solid or stranded wire up to 14 AWG — no special crimp tool or ferrule required for field termination, though ferrules are recommended for stranded wire in high-vibration panels.","metaTitle":"Omron E5CC-RX2ASM-006 Temperature Controller, 48x48 mm","metaDescription":"Omron E5CC-RX2ASM-006 digital temperature controller, 48x48 mm 1/16 DIN, universal input, relay control output, 100-240 VAC. Current lifecycle, screw terminals.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Process / Temperature Controllers"],"specifications":{"Size":"C = 48 × 48 mm","Options":"006 = Event inputs 1 and 2, and transfer output","Input type":"M = Universal input","Product No.":"E5CC-RX2ASM-006","Manufacturer":"Omron","Product Type":"Digital Temperature Controllers","Terminal type":"S = Screw terminals","Shipping Weight":"2 Kg","lifecycle_stage":"current","Control output 1":"R = Relay output","Control output 2":"X = None","Estimated Lead Time":"Usually ships in 1-10 working days.","Power supply voltage":"A = 100 to 240 VAC","Control Outputs 1 and 2":"Control output 1 : R = Relay output Control output 2 : X = None","No. of auxiliary outputs":"2 = 2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c33744c991744c853cd00d401708803.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/E5CC-RX2ASM-006/alternatives.json"},"ai":{"faq":[{"question":"What is the panel cutout size for the E5CC-RX2ASM-006?","answer":"The controller has a 48x48 mm face, which is the standard 1/16 DIN form factor. The panel cutout is 45x45 mm per DIN 43700."},{"question":"Does the E5CC-RX2ASM-006 have a second control output?","answer":"No. Control output 2 is omitted (X = None). This is a single-loop controller with one relay output on control 1. The two auxiliary outputs are for alarms or events, not for a second actuator."},{"question":"What sensor types does the universal input support?","answer":"The universal input (M type) supports thermocouple (J, K, T, E, L, U, N, R, S, B, W), RTD (Pt100, JPt100), and analogue signals (0-10 V, 0-20 mA, 4-20 mA). Sensor type is configured in the controller setup."},{"question":"What does the 006 option add to this controller?","answer":"The 006 option adds two event inputs and a transfer output. Event inputs allow remote switching between preset temperature sets or latching a reset. The transfer output provides a retransmission signal (4-20 mA or 0-10 V) proportional to the process value or set point."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/E5CC-RX2ASM-006","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/E5CC-RX2ASM-006 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}