{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"E5CC-TCQ3D5M-001","brand":"Omron","brandSlug":"omron","productSlug":"E5CC-TCQ3D5M-001","canonicalUrl":"https://aoctrl.com/omron/E5CC-TCQ3D5M-001","factsUrl":"https://aoctrl.com/api/mcp/products/E5CC-TCQ3D5M-001","rawCanonicalId":null},"summary":{"shortDescription":"Omron E5CC-TCQ3D5M-001 process/temperature controller, E5CC-T series, 24VAC/DC, PID control, 3 relay + analog + SSR outputs, IP66 front panel, 45mm square cutout.","salesMarkdown":"## Sensor input flexibility and what it means for your loop The E5CC-TCQ3D5M-001 accepts RTD and 13 thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) plus linear analog signals 0-20 mA or 0-10 VDC. That covers virtually every common process sensor — you can standardise one controller across multiple loop types without stocking different models. Input range spans -200°C to 2300°C for thermocouples, so it handles both cryogenic and high-temperature kiln/oven applications. The 0-20 mA and 0-10 VDC ranges let it accept pressure, flow, or level transmitter signals as well. ## Output architecture — three relays plus analog and SSR drive Three relay outputs handle on/off control, alarm annunciation, or valve positioning. The analog output (likely 4-20 mA or 0-10 VDC) provides a retransmitted process value or drives a proportional valve/actuator. The voltage pulse output fires an external SSR for fast-cycling heater loads — this combination means you don't need a separate signal conditioner or output expander for most single-loop applications. Control method is selectable between On/Off and proportional (PID). The PID algorithm includes auto-tuning, so commissioning is straightforward: wire the sensor and output, initiate the tune cycle, and the controller sets its own P, I, and D terms. Screw terminal connections simplify field wiring. IP66 front-panel rating means the display and keypad survive hose-down cleaning and dusty environments. The operating range is -10°C to 55°C, adequate for most indoor control panels but not for direct outdoor exposure without a weatherproof enclosure. ## Heater fault detection and event input Heater fault detection monitors the load current via an external CT and flags a broken heater or SSR short-circuit — critical for electric heaters where an undetected failure can cause process drift or safety issues. The event input allows remote switching between two setpoints or starting/stopping the control action, useful for interlocking with a safety circuit or a higher-level PLC.","metaTitle":"Omron E5CC-TCQ3D5M-001 Process Controller, 24VAC/DC, PID","metaDescription":"Omron E5CC-TCQ3D5M-001 temperature/process controller. 24VAC/DC supply, PID control, 3 relays + analog + SSR drive, IP66 front.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Process / Temperature Controllers"],"specifications":{"Type":"Process, Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)","Series":"E5CC-T","Weight":"0.265 lb (120.2 g)","Package":"Bulk","Features":"Event Input, Heater Fault Detection","Input Range":"-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC","Output Type":"Analog, Relay (3), Voltage (External SSR)","Display Type":"LCD - Dual Color Characters, Backlight","Mounting Type":"Panel Mount","Control Method":"On/Off, Proportional (PID)","lifecycle_stage":"current","Voltage - Supply":"24VAC/DC","Termination Style":"Screw Terminal","Ingress Protection":"IP66 - Dust Tight, Water Resistant","Operating Temperature":"-10°C ~ 55°C","Panel Cutout Dimensions":"Square - 45.00mm x 45.00mm","Display Characters - Height":"0.600\" (15.20mm), 0.280\" (7.10mm)","Number of Characters Per Row":"4, 4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6d2565f7c49acd020a74c22dc4212b3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/E5CC-TCQ3D5M-001/alternatives.json"},"ai":{"faq":[{"question":"What's the difference between E5CC-TCQ3D5M-001 and E5CC-TCQ3D5M-006?","answer":"The -006 variant is functionally identical except it omits the heater fault detection feature. If your application doesn't need to monitor heater current for broken-element or SSR-short detection, the -006 is a direct drop-in replacement at a lower cost. Same cutout, same wiring, same sensor input range."},{"question":"What compliance documentation does Omron provide for E5CC-TCQ3D5M-001?","answer":"Omron provides a declaration of conformity covering the applicable EU directives (EMC, Low Voltage, RoHS) and a CE mark. The controller is also UL/CSA listed. The specific certificate numbers are in the product drawing package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/E5CC-TCQ3D5M-001","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/E5CC-TCQ3D5M-001 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}