{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"E5EC-QX2DBM-011","brand":"Omron","brandSlug":"omron","productSlug":"E5EC-QX2DBM-011","canonicalUrl":"https://aoctrl.com/omron/E5EC-QX2DBM-011","factsUrl":"https://aoctrl.com/api/mcp/products/E5EC-QX2DBM-011","rawCanonicalId":null},"summary":{"shortDescription":"Omron E5EC series temperature controller, E5EC-QX2DBM-011, universal RTD/thermocouple input range -200°C to 2300°C, relay (3) and voltage (2) outputs, 24VAC/DC supply, PID control, IP66 front panel.","salesMarkdown":"## What it fits — the E5EC-QX2DBM-011 in a panel The E5EC-QX2DBM-011 is a 1/16 DIN-size temperature controller from Omron's E5EC series. It accepts a wide range of sensor inputs — RTD and thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W — covering the full spread from cryogenic to furnace work. The input range spans -200°C to 2300°C, plus linear 0–20 mA and 0–10 VDC signals, so it handles most process loops without a signal conditioner. Control method is On/Off or full PID — the PID loop auto-tunes on demand, which saves time during commissioning on a new oven or oven zone. ## Outputs that matter on a line-down swap Three relay outputs handle the main load, alarm, or event functions. Two voltage-pulse outputs drive external SSRs directly — no interposing relay needed for the heating element call. Heater fault detection is built in. It monitors the load current through a separate CT input and flags a broken heater or SSR short before the process drifts. That feature alone can save a production batch on a temperature-critical line. Compared to the E5EC-RX2DBM-010 (four relay outputs, no voltage outputs), the QX2DBM-011 trades one relay for two SSR-drive channels — essential if the downstream contactor bank uses DC-switched SSRs. Panel mount with a 92.00 mm x 45.00 mm rectangular cutout. Spring-terminal connections on the back. The front bezel is rated IP66 — dust-tight and protected against hose-down. That means it can sit on a washdown panel face in a food plant or a wet grinding area without a cover. The tri-color LCD backlight shows four characters per row across three rows — process value, setpoint, and status in one glance.","metaTitle":"Omron E5EC-QX2DBM-011 Temperature Controller, PID, 24VAC/DC","metaDescription":"Active-production Omron E5EC-QX2DBM-011 temperature controller.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Process / Temperature Controllers"],"specifications":{"Type":"Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)","Series":"E5EC","Weight":"0.463 lb (210.01 g)","Package":"Box","Features":"Heater Fault Detection","Input Range":"-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC","Output Type":"Relay (3), Voltage (External SSR) (2)","Display Type":"LCD - Tri Color Characters, Backlight","Mounting Type":"Panel Mount","Control Method":"On/Off, Proportional (PID)","lifecycle_stage":"current","Voltage - Supply":"24VAC/DC","Termination Style":"Spring Terminal","Ingress Protection":"IP66 - Dust Tight, Water Resistant","Operating Temperature":"-10°C ~ 55°C","Panel Cutout Dimensions":"Rectangular - 92.00mm x 45.00mm","Display Characters - Height":"0.710\" (18.00mm), 0.433\" (11.00mm), 0.307\" (7.80mm)","Number of Characters Per Row":"4, 4, 4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6d2565f7c49acd020a74c22dc4212b3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/E5EC-QX2DBM-011/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the Omron E5EC-QX2DBM-011 and get a price?","answer":"The E5EC-QX2DBM-011 is sourced to order against an RFQ through independent distribution."},{"question":"What is the difference between E5EC-QX2DBM-011 and E5EC-RX2DBM-010?","answer":"The QX2DBM-011 has three relay outputs plus two voltage-pulse outputs for external SSRs. The RX2DBM-010 has four relay outputs and no voltage outputs — choose the QX2 if your load circuit uses DC-switched SSRs, the RX2 if you need four discrete relay channels."},{"question":"Does E5EC-QX2DBM-011 support heater fault detection?","answer":"Yes, heater fault detection is a built-in feature. It monitors load current via an external CT and flags broken heaters or shorted SSRs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/omron/E5EC-QX2DBM-011","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/E5EC-QX2DBM-011 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}