{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ELNME4U22AAA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ELNME4U22AAA","canonicalUrl":"https://aoctrl.com/schneider/ELNME4U22AAA","factsUrl":"https://aoctrl.com/api/mcp/products/ELNME4U22AAA","rawCanonicalId":null},"summary":{"shortDescription":"MX eco 4V2.2 - variable speed drive - 2.2kW - 400V - 3PH - EMC - IP20","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"175 mm","Width":"130 mm","Height":"230 mm","Standards":"EN/IEC 61800-5-1 EN 50178 EN/IEC 60721-3-3 class 3C1 and 3S2 EN/IEC 61800-5-2 EN/IEC 61800-3 environments 1 and 2 category C1, C2, C3","EMC filter":"Integrated","Data format":"8 bits, odd even or no configurable parity for Modbus on terminal 8 bits, 1 stop, even parity for Modbus on front face","Noise level":"55 dB conforming to 86/188/EEC","Option card":"Communication card for Profibus DP Basic I/O extension card Extended I/O extension card","Line current":"8.2 A for 400 V, 3 phases, 2.2 kW (without choke) 7.1 A for 480 V, 3 phases, 3 hp (without choke)","Apparent power":"4 kVA for 400 V3 phases / 2.2 kW 4.6 kVA for 460 V3 phases / 3 hp","Assembly style":"Built-in unit with forced cooling","Braking torque":"30 % without braking resistor 1 mOhm 500 V DC for 1 minute to earth","Connector type":"1 RJ45 (on terminal) for Modbus Male SUB-D 9 on RJ45 for CANopen","Motor power hp":"3 hp 3 phases for 460 V","Motor power kW":"2.2 kW 3 phases for 380...480 V","Speed accuracy":"V/f mode: slip frequency without speed feedback VC without feedback: 0.3 x slip frequency","Torque accuracy":"+/- 15 % in open-loop mode, without speed feedback","lifecycle_stage":"unknown","Method of access":"Slave CANopen","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"MX eco","Shock resistance":"15 gn for 11 ms conforming to EN/IEC 60068-2-27","Supply frequency":"50...60 Hz +/-5 %","Device short name":"MX eco 4V2.2","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Transmission rate":"24...38400 bauds for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face 34 kbauds...1 Mbaud for CANopen","Operating altitude":"1000...3000 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485 for Modbus","Transmission frame":"RTU for Modbus","Number of addresses":"1...247 for Modbus 1...127 for CANopen","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...16 kHz adjustable 4...16 kHz with derating factor","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.01/50 Hz","Prospective line Isc":"5 kA 3 phases without choke 35 kA 3 phases with DCL-choke 100 kA 3 phases with line reactor","Transient overtorque":"120 % of nominal motor torque for 60 s 135 % of nominal motor torque for 2 s","Vibration resistance":"1.5 mm peak to peak (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-6","Supply voltage limits":"323...528 V","IP degree of protection":"IP20 top without protective cover conforming to EN/IEC 61800-5-1 and EN/IEC 60529 IP21 bottom, sideways and front conforming to EN/IEC 61800-5-1 and EN/IEC 60529 IP41 top conforming to EN/IEC 61800-5-1 and EN/IEC 60529","Network frequency limits":"47.5...63 Hz","Network number of phases":"3 phases","Continuous output current":"5.8 A at 4 kHz, 400 V3 phases 5.8 A at 4 kHz, 460 V3 phases","Maximum transient current":"7 A for 60 s 3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Communication port protocol":"CANopen Modbus","Nominal switching frequency":"4 kHz","Product specific application":"Pumping and ventilation machine","Speed drive output frequency":"0...300 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...50 °Cwithout derating 50...60 °Cwith current derating of 2 % per °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/my/en/product/ELNME4U22AAA/mx-eco-4v2-2-variable-speed-drive-2-2kw-400v-3ph-emc-ip20/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ELNME4U22AAA/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ELNME4U22AAA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ELNME4U22AAA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}