{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13201","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13201","canonicalUrl":"https://aoctrl.com/schneider/ENW13201","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13201","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW ENW13201, 3P drawout circuit breaker, 630 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"Schneider Electric ENW13201 is a 3-pole drawout circuit breaker from the EasyPact NW family, rated 630 A at 40 °C with a breaking capacity of 66 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2. ## Drawout mounting and panel integration Mounts on a rail base plate with drawout mechanism — the breaker can be racked out for maintenance or replacement without disturbing the main bus connections. Rear connection terminals accept horizontal or vertical bus bars; connection pitch is 70 mm without a spreader. Overall dimensions are 288 mm wide × 322 mm high × 277 mm deep, so plan for a cutout that accommodates the drawout cradle plus clearance for arc chute venting. Rated for 20,000 mechanical cycles with maintenance (10,000 without) and 5,000 electrical cycles at 440 V AC without maintenance — this is a Category B breaker, meaning it's designed for selective coordination with downstream devices.","metaTitle":"Schneider Electric ENW13201 EasyPact NW Circuit Breaker, 630","metaDescription":"Schneider Electric ENW13201 EasyPact NW drawout circuit breaker, 630 A rated current, 66 kA Icu at 440 V AC, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"277 mm","Width":"288 mm","Height":"322 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP30","Application":"Distribution","Product Status":"Active","Terminal Pitch":"70 mm without spreader","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Utilization Category":"Category B","Mechanical Life Cycles":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-5...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d1836c1a0872559801b427738a586f99.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13201/circuit-breaker-frame-adapt-easypact-nw-3-poles-630a-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW13201/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13201","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13201 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}