{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13202","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13202","canonicalUrl":"https://aoctrl.com/schneider/ENW13202","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13202","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW13202 circuit breaker, 3P, 800 A rated current at 40 °C, 66 kA Icu at 220-440 V AC, drawout mounting.","salesMarkdown":"The Schneider Electric ENW13202 is an EasyPact NW drawout circuit breaker rated 800 A at 40 °C, with a 66 kA Icu breaking capacity at 220-440 V AC 50/60 Hz per IEC 60947-2. The 55 kA Ics service breaking capacity tells you it can clear a fault and be reclosed without maintenance, which matters for continuous-process lines where a nuisance trip can't wait for a breaker swap. ## Drawout mounting and panel integration This breaker mounts on a rail base plate with a drawout mechanism — the 277 mm depth and 288 mm width fit standard switchgear cubicles. Rear horizontal or vertical connection positions give flexibility for busbar routing. The 70 mm connection pitch without spreader matches common busbar drilling patterns. ## Key ratings and standards Rated insulation voltage 1000 V AC, impulse withstand 12 kV. Short-time withstand current 50 kA for 1 s — that's the thermal limit for a delayed trip coordination study. Making capacity 75 kA Icm. Maximum breaking time 35 ms, closing time 70 ms. IP30 protection — indoor panel use only, not for washdown environments.","metaTitle":"Schneider Electric EasyPact NW ENW13202 Circuit Breaker, 800","metaDescription":"Schneider Electric ENW13202 EasyPact NW circuit breaker, 800 A rated current at 40 °C, 66 kA Icu at 220-440 V AC, IEC 60947-2. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"277 mm","Range":"EasyPact","Width":"288 mm","title":"ENW13202","Height":"322 mm","Standards":"IEC 60947-2","description":"Circuit breaker frame, adapt EasyPact NW, 3 Poles, 800A, withdrawal","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW08C","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"800 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"35 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"C","Location of connection":"Rear","IP degree of protection":"IP30","Circuit breaker CT rating":"800 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"75 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/25b226c3355d4d2f8607b8b0705566f2.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW13202/circuit-breaker-frame-adapt-easypact-nw-3-poles-800a-withdrawal/"},"ai":{"faq":[{"question":"Where can I buy ENW13202 and how is it quoted?","answer":"The ENW13202 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is ENW13202's breaking capacity at 440 V?","answer":"The ENW13202 has a 66 kA Icu breaking capacity at 220-440 V AC 50/60 Hz per IEC 60947-2, and a 55 kA Ics service breaking capacity at the same voltage."},{"question":"What compliance documentation does Schneider provide for ENW13202?","answer":"The breaker is certified to IEC 60947-2 and carries a suitability-for-isolation declaration. For RoHS, REACH, or UL documentation, the manufacturer's compliance portal provides the current declarations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13202","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13202 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}