{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13204","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13204","canonicalUrl":"https://aoctrl.com/schneider/ENW13204","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13204","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW13204, 3-pole drawout circuit breaker, 1250 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"## 1250 A drawout breaker for distribution — ENW13204 The Schneider Electric ENW13204 is a 3-pole drawout circuit breaker from the EasyPact NW range, rated 1250 A at 40 °C and built to IEC 60947-2 for distribution duty. The 55 kA Ics service breaking capacity (same voltage range) tells you it can reclose after a fault at that level, not just survive one. Drawout mounting allows the breaker to slide out of its cradle for inspection or swap without disturbing bus connections. The 50 kA Icw short-time withstand for 1 second supports selective coordination. The 5000-cycle electrical durability without maintenance and 10,000 cycles mechanical without maintenance are the numbers a reliability engineer checks for a high-cycle application like a capacitor bank or furnace transformer. With maintenance, mechanical durability stretches to 20,000 cycles.","metaTitle":"Schneider Electric ENW13204 EasyPact NW Circuit Breaker, 125","metaDescription":"Schneider Electric ENW13204 EasyPact NW drawout circuit breaker, 1250 A rated current, 66 kA Icu at 440 V AC, IEC 60947-2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"277 mm","Width":"288 mm","Height":"322 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP30","Application":"Distribution","Product Status":"Active","Terminal Pitch":"70 mm without spreader","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Utilization Category":"Category B","Mechanical Life Cycles":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-5...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d8bc9e4bfb63e9b0bf65dff8163d0938.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13204/circuit-breaker-frame-adapt-easypact-nw-3-poles-1250a-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW13204/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13204","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13204 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}