{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13221","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13221","canonicalUrl":"https://aoctrl.com/schneider/ENW13221","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13221","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW13221, 4-pole drawout circuit breaker, 1600 A rated current, 66 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"## What this breaker delivers The ENW13221 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1600 A at 40 °C and built to IEC 60947-2. The 55 kA Ics (service breaking capacity) tells you it can reclose after that fault and keep running, not just survive once. ## Drawout mounting and panel fit Drawout mounting means the breaker chassis stays wired to the bus; the moving portion slides out for maintenance or swap without pulling cables. The footprint is 358 mm wide × 322 mm high × 277 mm deep — sit that against your existing switchgear cubicle cutout. Rear connection with a 70 mm pitch without spreader keeps phase spacing predictable for busbar drilling. IP30 is bare-enclosure; in a typical IP54 panel the door gasket handles the rest.","metaTitle":"ENW13221 EasyPact NW Drawout Circuit Breaker, 1600 A, 66 kA","metaDescription":"ENW13221 EasyPact NW drawout circuit breaker, 1600 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2. Active production, sourced to order. Request quote for pricing and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"277 mm","Width":"358 mm","Height":"322 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP30","Application":"Distribution","Product Status":"Active","Terminal Pitch":"70 mm without spreader","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Utilization Category":"Category B","Mechanical Life Cycles":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-5...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8ecbc7412921899ed334622538e5caba.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13221/circuit-breaker-frame-adapt-easypact-nw-4-poles-1600a-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW13221/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13221","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13221 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}