{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13226","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13226","canonicalUrl":"https://aoctrl.com/schneider/ENW13226","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13226","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW13226, circuit breaker, 800 A, 66 kA Icu at 440 V AC, 4P, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW13226 is an EasyPact NW fixed-mount circuit breaker rated for 800 A at 40 °C, with a 66 kA Icu breaking capacity at 220...440 V AC 50/60 Hz per IEC 60947-2. It's a 4-pole unit (4P 3d protected poles) built for distribution duty in switchboards and industrial panels. Both are verified at 440 V AC, the common industrial distribution voltage. The 50 kA Icw for 1 second tells you it can withstand a delayed trip from a downstream device, so you can build a selective cascade without worrying about the main blowing first. ## Integration into the switchboard This breaker mounts fixed to a rail base plate, rear-connected, with a 70 mm connection pitch without spreader. At 346 mm wide, 301 mm high, and 196 mm deep, it fits standard low-voltage switchgear cubicles. The neutral sits on the left. IP30 protection is basic finger-probe protection on the front; the real sealing happens in the enclosure.","metaTitle":"Schneider Electric ENW13226 EasyPact NW Circuit Breaker, 800","metaDescription":"Schneider Electric ENW13226 EasyPact NW circuit breaker, 800 A rated current, 66 kA Icu at 440 V AC, 4P, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"196 mm","Range":"EasyPact","Width":"346 mm","Height":"301 mm","Standards":"IEC 60947-2","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW08C","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"800 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"35 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"C","Location of connection":"Rear","IP degree of protection":"IP30","Circuit breaker CT rating":"800 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"4P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"75 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8429660d4991fa79fec8ede863fddf7c.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13226/circuit-breaker-frame-adapt-easypact-nw-4-poles-800a-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW13226/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW13226 and how do I get a price?","answer":"The ENW13226 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What is ENW13226's breaking capacity at 440 V?","answer":"The ENW13226 has a 66 kA Icu (ultimate breaking capacity) and a 55 kA Ics (service breaking capacity) at 220...440 V AC 50/60 Hz per IEC 60947-2."},{"question":"What standards does the ENW13226 comply with?","answer":"The ENW13226 complies with IEC 60947-2 for circuit breakers, with a rated insulation voltage of 1000 V AC, impulse withstand voltage of 12 kV, and pollution degree 3 per IEC 60664-1."},{"question":"What is the mechanical durability of the ENW13226?","answer":"The ENW13226 is rated for 20,000 cycles with maintenance and 10,000 cycles without maintenance, per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13226","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13226 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}