{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13228","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13228","canonicalUrl":"https://aoctrl.com/schneider/ENW13228","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13228","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW13228, 1250 A, 66 kA Icu at 220-440 V AC, 4P, fixed mount.","salesMarkdown":"The Schneider Electric ENW13228 is a 4-pole EasyPact NW air circuit breaker rated 1250 A at 40 °C, built for distribution duty in AC networks at 50/60 Hz. The 55 kA Ics service breaking capacity tells you it can reclose after a fault at that level and still carry rated load, not just survive one shot. Rated insulation voltage (Ui) of 1000 V AC and impulse withstand (Uimp) of 12 kV per IEC 60947-2. The 50 kA Icw for 1 second supports selective coordination studies. Mechanical durability of 20,000 cycles with maintenance and 10,000 without, plus electrical endurance of 5,000 cycles at 440 V without maintenance, puts this in the heavy-industrial bracket — not a daily-switch application, but fine for infrequent load-break or isolation duty.","metaTitle":"Schneider Electric ENW13228 EasyPact NW Circuit Breaker, 125","metaDescription":"Schneider Electric ENW13228 EasyPact NW circuit breaker, 1250 A at 40 °C, 66 kA Icu at 220-440 V AC, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"196 mm","Range":"EasyPact","Width":"346 mm","Height":"301 mm","Standards":"IEC 60947-2","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW12C","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"1250 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"35 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"C","Location of connection":"Rear","IP degree of protection":"IP30","Circuit breaker CT rating":"1250 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"4P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"75 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f56b5e98143e64babf581b5dbe9639da.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13228/circuit-breaker-frame-adapt-easypact-nw-4-poles-1250a-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW13228/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of ENW13228?","answer":"The ENW13228 has a rated ultimate breaking capacity (Icu) of 66 kA at 220-440 V AC 50/60 Hz per IEC 60947-2, and a service breaking capacity (Ics) of 55 kA at the same voltage."},{"question":"What compliance documentation does Schneider provide for ENW13228?","answer":"The breaker is certified to IEC 60947-2, with a rated insulation voltage of 1000 V AC and impulse withstand of 12 kV. It is suitable for isolation per the same standard. Specific RoHS/REACH/UL documentation should be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13228","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13228 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}