{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13265","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13265","canonicalUrl":"https://aoctrl.com/schneider/ENW13265","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13265","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW switch disconnector, ENW13265, 3 poles, 630 A AC-23A, drawout mount, 1000 V insulation, 50 kA short-time withstand.","salesMarkdown":"The ENW13265 is a 3-pole switch disconnector from the EasyPact NW range, rated 630 A in AC-23A utilisation category at 440 V AC — that is the motor-switching duty class, so it handles high inrush from inductive loads like conveyors or compressors without derating. It is a drawout (withdrawable) unit, meaning the switching element can be racked out from the cradle for safe isolation and maintenance while the enclosure stays wired. Rated operational current is 630 A in AC-23A at 440 V — that is the current it can make and break repeatedly for motor loads. Below that, the rated short-time withstand current (Icw) is 50 kA for 1 second at 220–440 V, and the rated short-circuit making capacity (Icm) is 75 kA at the same voltage range. These numbers tell you the switch can survive and close into a fault up to 75 kA peak, and can carry 50 kA RMS for one second while upstream protection clears — critical for selective coordination studies. Rated insulation voltage (Ui) is 1000 V AC, and impulse withstand (Uimp) is 12 kV, so it is comfortable in 690 V systems or where transient overvoltages are common. Mounting is drawout on a rail base plate — the fixed part (cradle) bolts into the enclosure, and the switch unit slides in and out. Connection pitch is 70 mm without a spreader, and connections are at the rear, vertical or horizontal orientation. Panel builders should allow for the 322 mm height, 288 mm width, and 277 mm depth when laying out the gland plate and busbar runs. IP30 protection means it is not washdown-rated but fine inside a locked enclosure. No official successor exists because none is needed.","metaTitle":"ENW13265 EasyPact NW Switch Disconnector, 630 A, 3P, Drawout","metaDescription":"ENW13265 EasyPact NW switch disconnector, 630 A AC-23A, 3 poles, drawout mount. IEC 60947-3. Active production. Sourced to order. Request RFQ for pricing and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"277 mm","Range":"EasyPact","Width":"288 mm","title":"ENW13265","Height":"322 mm","Standards":"IEC 60947-3","description":"switch disconnector, EasyPact NW, 3 Poles, 630A, AC, withdrawable","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW06CA","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"CA","Location of connection":"Rear","IP degree of protection":"IP30","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 630 A AC 50/60 Hz 440 V","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at 220...440 V","[Icm] rated short-circuit making capacity":"75 kA 220...440 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe479c7871e6141aa98628d40e344e9f.pdf","sourceUrl":"https://www.se.com/eg/en/product/ENW13265/switch-disconnector-easypact-nw-3-poles-630a-ac-withdrawable/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW13265?","answer":"Pricing and availability are confirmed at quote time against an RFQ — submit a request and we will source it through our independent distribution channel."},{"question":"What is the closest alternative to ENW13265 in the EasyPact NW family?","answer":"Within the same EasyPact NW drawout range, the closest alternative would be a different breaking capacity code or pole count — but the ENW13265 is a standard active part, so no direct substitute is needed unless your BOM calls for a different current rating or poles."},{"question":"What is ENW13265's depth?","answer":"The depth is 277 mm."},{"question":"What compliance documentation does Schneider provide for ENW13265?","answer":"The switch disconnector is designed and tested to IEC 60947-3, with a rated insulation voltage of 1000 V AC and impulse withstand of 12 kV. For specific RoHS, REACH, or UL documentation, request the manufacturer's compliance declarations at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13265","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13265 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}