{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13268","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13268","canonicalUrl":"https://aoctrl.com/schneider/ENW13268","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13268","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, switch disconnector, ENW13268, 3 poles, 1250 A AC-23A, drawout, 277 x 288 x 322 mm.","salesMarkdown":"The ENW13268 is a Schneider Electric EasyPact NW switch disconnector, 3 poles, rated 1250 A in AC-23A utilisation category at 440 V AC. That AC-23A rating means it handles motor loads with occasional overloads — switching, not just isolating — so it's sized for distribution and motor feeder duty in industrial panels. Drawout mounting on a rail base plate lets you rack the unit out for maintenance without unbolting bus connections, which cuts downtime on a line changeover. Drawout mounting on a rail base plate, rear connection, vertical or horizontal orientation. Connection pitch is 70 mm without a spreader. The 277 mm depth, 288 mm width, and 322 mm height fit standard switchgear cubicle compartments. IP30 finger protection on the enclosure; inside a locked cabinet that's sufficient. Rated insulation voltage 1000 V AC, impulse withstand 12 kV. Short-time withstand 50 kA for 1 second at 220–440 V; making capacity 75 kA at the same voltage range. That 50 kA Icw means it coordinates with upstream breakers rated for that fault level without needing a separate current-limiting fuse. The 5000-cycle electrical durability at 440 V AC-23A and 20000-cycle mechanical durability (with maintenance) give a realistic service life for a distribution disconnector that sees infrequent switching. Suitability for isolation confirmed per IEC 60947-3, with a visible contact position indicator. Standards compliance to IEC 60947-3 covers the switching and isolation performance. Network frequency 50/60 Hz, so it works on either without derating.","metaTitle":"ENW13268 EasyPact NW Switch Disconnector, 1250 A, 3P, Drawou","metaDescription":"ENW13268 EasyPact NW switch disconnector, 1250 A AC-23A, 3 poles, drawout mounting. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"277 mm","Range":"EasyPact","Width":"288 mm","title":"ENW13268","Height":"322 mm","Standards":"IEC 60947-3","description":"switch disconnector, EasyPact NW, 3 Poles, 1250A, AC, withdrawable","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW12CA","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"CA","Location of connection":"Rear","IP degree of protection":"IP30","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1250 A AC 50/60 Hz 440 V","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at 220...440 V","[Icm] rated short-circuit making capacity":"75 kA 220...440 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/74fe28b411d8cd81938f14625845da80.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13268/switch-disconnector-easypact-nw-3-poles-1250a-ac-withdrawable/"},"ai":{"faq":[{"question":"Where can I buy ENW13268 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is ENW13268's rated operational current?","answer":"1250 A in AC-23A utilisation category at 440 V AC, 50/60 Hz, per IEC 60947-3."},{"question":"What compliance documentation does this brand provide for ENW13268?","answer":"The switch disconnector is designed and tested to IEC 60947-3. Pollution degree 3 per IEC 60664-1. No specific RoHS, REACH, or UL listing is stated in the available documentation."},{"question":"What is the closest alternative to ENW13268 in this component family?","answer":"Within the EasyPact NW range, the closest functional sibling would be a 3-pole drawout switch disconnector with a different breaking capacity code or current rating. The ENW13268 uses breaking capacity code CA; a unit with code CB or a different current would change the short-time withstand or making capacity. No pin-compatible drop-in exists across current ratings — the drawout cradle and bus connections scale with the frame."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13268","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13268 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}