{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW13281","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW13281","canonicalUrl":"https://aoctrl.com/schneider/ENW13281","factsUrl":"https://aoctrl.com/api/mcp/products/ENW13281","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW switch disconnector, ENW13281, 3-pole drawout, 1250 A rated operational current (AC-23A at 440 V), IEC 60947-3.","salesMarkdown":"It carries a 1250 A rated operational current in utilisation category AC-23A at 440 V AC (50/60 Hz), meaning it handles the high inrush of motor loads and other inductive switching without derating — not just resistive break. The drawout mounting lets you rack the unit out for safe isolation without disturbing the power wiring, a key feature for panel maintenance or fault isolation in a live enclosure. Short-time withstand (Icw) is 50 kA for 1 second at 220–440 V — that is the fault current the disconnector can carry without welding or damage until an upstream breaker clears. Short-circuit making capacity (Icm) is 75 kA at the same voltage range, confirming it can close onto a fault without destroying itself. Mounts on a rail base plate with a drawout mechanism. The connection pitch is 70 mm without a spreader; rear connection supports both vertical and horizontal busbar arrangements. IP30 protection means it is splash-proof against tools and fingers but not water jets — suitable for enclosed switchgear, not washdown areas. The contact position indicator gives a visual open/closed state at a glance, which speeds up lockout-tagout verification.","metaTitle":"Schneider Electric ENW13281 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW13281 EasyPact NW switch disconnector, 1250A rated operational current AC-23A at 440V, 3-pole drawout, IEC 60947-3. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"277 mm","Range":"EasyPact","Width":"358 mm","title":"ENW13281","Height":"322 mm","Standards":"IEC 60947-3","description":"switch disconnector, EasyPact NW, 4 Poles, 1250A, withdrawable","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"70 mm without spreader","Mounting support":"Rail Base plate","Pollution degree":"3 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW12CA","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"CA","Location of connection":"Rear","IP degree of protection":"IP30","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1250 A AC 50/60 Hz 440 V","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at 220...440 V","[Icm] rated short-circuit making capacity":"75 kA 220...440 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2b05738efc8af12d2d048f784008d9da.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW13281/switch-disconnector-easypact-nw-4-poles-1250a-withdrawable/"},"ai":{"faq":[{"question":"Where can I buy the ENW13281 and what is the lead time?","answer":"The ENW13281 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."},{"question":"What is the closest alternative to ENW13281 in the EasyPact NW family?","answer":"The ENW13281 is a 3-pole 1250 A drawout disconnector. A different pole count or current rating (e.g., 1600 A or 2000 A) would be a different order code within the EasyPact NW range, but no pin-compatible alternative exists — the drawout cradle and busbar pitch are specific to this rating."},{"question":"What compliance documentation does Schneider provide for ENW13281?","answer":"The ENW13281 is designed to IEC 60947-3 and carries a rated insulation voltage of 1000 V AC, impulse withstand of 12 kV, and pollution degree 3 per IEC 60664-1. Standard Schneider documentation includes the declaration of conformity for the applicable directives; specific RoHS/REACH/UL status should be confirmed from the product certificate available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW13281","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW13281 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}