{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW15562","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW15562","canonicalUrl":"https://aoctrl.com/schneider/ENW15562","factsUrl":"https://aoctrl.com/api/mcp/products/ENW15562","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, Trip System 2.0 control unit, drawout and fixed mounting, LI protection, 630...6300 A, 690 V AC.","salesMarkdown":"The ENW15562 is a microprocessor-based Trip System 2.0 control unit for the Schneider Electric EasyPact NW range of air circuit breakers. It provides LI protection — overload (long-time) and instantaneous short-circuit — for standard industrial applications on AC networks at 50/60 Hz. The trip unit rating spans 630 to 6300 A, and the long-time pick-up (Ir) is adjustable from 0.4 to 1 x In, with ten settings each for both Ir and the instantaneous pick-up (Ii) range of 1.5 to 10 x Ir. That granularity lets you fine-tune the curve to the load without swapping hardware. The long-time delay (Tr) is adjustable from 0.5 to 24 s at 6 x Ir, with an accuracy of 0 to -20%. This sets how long the breaker holds during a sustained overload before tripping — critical for coordinating with downstream feeders and avoiding nuisance trips on motor starting inrush. Thermal memory is included, so the trip unit tracks the thermal history of the conductor after a trip. If you reclose quickly, the remaining thermal capacity is accounted for — prevents re-energizing into an already-hot circuit. Fault indication covers overload, short-circuit, and internal fault — three distinct LED states on the front face. That saves panel walk-down time during commissioning or post-fault diagnostics: you see what type of event caused the trip without plugging in a laptop. Mounting mode is drawout and fixed, meaning the same control unit fits both the drawout cradle and the fixed-mount breaker chassis. The neutral position is left, and protected poles can be configured as 3D, 4D, or 3D + N/2 — the neutral protection setting is selectable from off, 0.5 x Ir, or 1 x Ir.","metaTitle":"ENW15562 EasyPact NW Trip System 2.0 Control Unit, LI Protec","metaDescription":"ENW15562 Trip System 2.0 control unit for EasyPact NW circuit breakers. LI protection, microprocessor-based, 630-6300 A, 690 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"77 mm","Width":"58 mm","Height":"200 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Product Status":"Active","Trip Unit Type":"Micro-processor based","Temp Storage Max":"85 °C","Temp Storage Min":"-25 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-25...85 °C","Main Product Or Component Type":"Control unit","Ambient Air Temperature Operation":"-5...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/58a9b0f45c1007865f31e812bab07cf0.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW15562/trip-unit-easypact-nw-trip-system-2-0-drawout-and-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW15562/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW15562","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW15562 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}