{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW21419","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW21419","canonicalUrl":"https://aoctrl.com/schneider/ENW21419","factsUrl":"https://aoctrl.com/api/mcp/products/ENW21419","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, Trip System 6.0E control unit, LSIG protection, 800-4000 A, 690 V AC, drawout mounting.","salesMarkdown":"The Schneider Electric ENW21419 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. The trip unit rating spans 800 to 4000 A, making it suitable for main or feeder breaker duty in large switchboards. Rated operational voltage of 690 V AC conforming to IEC 60947-2 means this unit is certified for the standard industrial voltage level up to 690 V phase-to-phase. The trip unit rating of 800-4000 A covers the full range of EasyPact NW frame sizes; the actual setting is configured by the user. LSIG protection functions (overload, short-time, instantaneous, earth fault) are all adjustable — long-time pick-up (Ir) has 9 settings from 0.4 to 1 x In, short-time pick-up (Isd) has 9 settings from 1.5 to 10 x Ir, and instantaneous pick-up (Ii) has 9 settings from 2 to 15 x In. The ground-fault pick-up (Ig) ranges from 0.2 to 1 x In for frames up to 1000 A, and 500 to 1200 A for frames 1250 A and above. This adjustability lets the protection engineer coordinate the breaker with downstream devices without swapping hardware. Zone selective interlocking (ZSI) is built in, meaning this unit can communicate with upstream and downstream breakers to reduce arcing fault energy while maintaining selectivity. The control unit mounts via drawout mechanism into the EasyPact NW breaker cradle. Drawout mounting allows the unit to be racked out for maintenance or replacement without de-energizing the bus — standard for main breakers in industrial switchgear where uptime matters. The physical dimensions are 200 mm height, 55 mm width, and 75 mm depth, fitting the standard EasyPact NW cutout. The digital display provides local readout of metering data (energy, current, voltage) and fault indication for short-circuit, earth fault, internal fault, and overload.","metaTitle":"Schneider Electric ENW21419 EasyPact NW Trip System 6.0E, 80","metaDescription":"ENW21419 is a Schneider Electric EasyPact NW microprocessor-based control unit with Trip System 6.0E, rated 800-4000 A, 690 V AC, LSIG protection. Active lifecycle, available to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"75 mm","Width":"55 mm","Height":"200 mm","Display type":"Digital display","Network type":"AC","Mounting mode":"Drawout","Thermal memory":"20 minutes before and after tripping","Trip unit name":"Trip System 6.0E","Protection type":"Overload protection (long time) Earth fault Short time short-circuit protection Instantaneous short-circuit protection","lifecycle_stage":"current","Fault indication":"Short-circuit Earth fault Internal fault Overload","Neutral position":"Left","Range of product":"EasyPact NW","Trip unit rating":"800...4000 A","Network frequency":"50/60 Hz","Poles description":"4P 3P","Type of measurement":"Energy meter","Trip unit technology":"Micro-processor based","Product or component type":"Control unit","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Circuit breaker application":"Industrial Standard","Protected poles description":"3D + N/2 3D 4D","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-25...85 °C","Ground-fault pick-up adjustment type":"Adjustable 9 settings","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s (6 x Ir), accuracy: 0...- 20 %","Instantaneous pick-up adjustment range":"2...15 x In, accuracy: +/- 10 % Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir","[Ig] ground-fault pick-up adjustment range":"0.2...1 x In (400 A < In =< 1000 A), accuracy: +/- 10 % 500...1200 x In (In >= 1250 A), accuracy: +/- 10 %","Ground-fault time delay adjustment type -tg":"Adjustable 5 settings","[Tg] Ground-Fault Time Delay Adjustment Range":"100...400 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e3a23e4f63046d35402fd1e1bc903384.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW21419/trip-unit-easypact-nw-tse6g-drawout/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW21419/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW21419?","answer":"The ENW21419 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation at quote time."},{"question":"What is the closest alternative to ENW21419 in the EasyPact NW family?","answer":"The ENW21419 is the active Trip System 6.0E control unit; no direct successor or pin-compatible alternative exists within the EasyPact NW range. Other trip units in the family (Trip System 5.0, 7.0) offer different protection profiles but are not drop-in replacements without changing the breaker cradle configuration."},{"question":"What compliance documentation does Schneider provide for ENW21419?","answer":"The ENW21419 is certified to IEC 60947-2 for rated operational voltage of 690 V AC. Standard Schneider documentation includes the declaration of conformity and IEC certification. RoHS and REACH compliance declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW21419","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW21419 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}