{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW21513","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW21513","canonicalUrl":"https://aoctrl.com/schneider/ENW21513","factsUrl":"https://aoctrl.com/api/mcp/products/ENW21513","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, closing coil, electrically operated, drawout, 380/480 V AC 50/60 Hz, 4.5 W/4.5 VA holding power, ENW21513.","salesMarkdown":"The Schneider Electric ENW21513 is a closing coil in the EasyPact NW range, electrically operated with a maintained control signal. It's the pull-in component for the XF drawout circuit breaker — the coil that closes the main contacts when energized. Rated for 380/480 V AC 50/60 Hz control voltage, it draws 4.5 W / 4.5 VA holding power once sealed. ## Drawout mounting and panel integration This coil mounts in a drawout chassis — the breaker racking mechanism. That means the coil is part of the removable cradle, not the fixed enclosure. For a turnaround planner: the drawout design lets you swap the entire breaker (including this coil) in minutes without unbolting line-side cables. The coil itself is a field-replaceable cartridge inside the cradle; if it fails, you pull the breaker to the disconnected position, release the coil retaining clip, and slide in a replacement. No need to de-energize the bus if the breaker is racked out. ## What the control voltage rating means for fit For a site electrical engineer checking selectivity: this coil is designed for the EasyPact NW drawout breaker family (XF designation). It's not a universal replacement for fixed-mount breakers or other manufacturer's coils. The maintained control signal type means the coil stays energized continuously to keep the breaker closed; a momentary pulse won't hold it. That's standard for closing coils in drawout gear — the control scheme must provide sustained voltage or use a latch-check relay in series.","metaTitle":"Schneider ENW21513 EasyPact NW Closing Coil, 380/480VAC, Dra","metaDescription":"ENW21513 EasyPact NW closing coil, electrically operated, 380/480 VAC 50/60 Hz, drawout mount, 4.5 W/4.5 VA hold. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Range":"EasyPact","Control type":"Electrically operated","Mounting mode":"Drawout","lifecycle_stage":"current","Range of product":"EasyPact NW","Device short name":"XF","Device application":"Control","Control signal type":"Maintained","Supply holding power":"4.5 W 4.5 VA","Voltage release type":"Closing coil","Product or component type":"Closing coil","[Uc] control circuit voltage":"380/480 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f34544ed09f82a528448e874b23ee945.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW21513/coil-easypact-nw-mx-xf-mch-380-415vac-drawout/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW21513/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage range for ENW21513?","answer":"380/480 V AC 50/60 Hz. The coil is rated for that band and pulls in reliably across it."},{"question":"What is the holding power of the ENW21513 coil?","answer":"4.5 W and 4.5 VA once the coil is sealed. That's the steady-state draw after the initial inrush."},{"question":"What breaker range does ENW21513 belong to?","answer":"The EasyPact NW range, device short name XF. It's the closing coil for drawout breakers in that family."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW21513","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW21513 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}