{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW21526","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW21526","canonicalUrl":"https://aoctrl.com/schneider/ENW21526","factsUrl":"https://aoctrl.com/api/mcp/products/ENW21526","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, XF closing coil, 48/60 VDC, electrically operated, maintained control, 4.5 W/VA holding power, fixed mounting.","salesMarkdown":"## Closing coil for EasyPact NW — 48/60 VDC, electrically operated The ENW21526 is a closing coil for the Schneider Electric EasyPact NW range — a fixed-mount, electrically operated coil (XF device short name) that draws and holds the main contacts closed on maintained control signals. Control circuit voltage is 48/60 V DC, with a holding power draw of 4.5 W / 4.5 VA. The 48/60 V DC control voltage is a dual-range coil — it operates on either nominal, so a 48 VDC control supply or a 60 VDC battery-backed bus both work without a separate dropping resistor. The 4.5 W / 4.5 VA holding power is low enough that a standard 24 VDC pilot-device transformer with a rectifier can supply it, but confirm the inrush at pickup if the coil is cycled frequently — the holding figure is steady-state, not peak pull-in. The electrically operated, maintained control type means the coil stays energized to keep the breaker closed; a loss of control power drops the breaker open (trip-free mechanism). ## Integration into the EasyPact NW breaker This is a fixed-mount accessory for the EasyPact NW air circuit breaker family. It installs into the breaker's mechanism housing; no DIN-rail or panel cutout required — it's internal to the breaker chassis. The XF designation indicates the closing-coil variant, distinct from the MX shunt trip or MCH motor-mechanism coils in the same range. Verify breaker frame compatibility: the EasyPact NW covers NW08 through NW63 frames; the coil's mechanical interface is common across the range, but the control-wire routing differs between draw-out and fixed versions.","metaTitle":"ENW21526 EasyPact NW Closing Coil, 48/60 VDC, Active","metaDescription":"ENW21526 EasyPact NW closing coil (XF type), 48/60 VDC, 4.5 W/VA holding power. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Range":"EasyPact","Control type":"Electrically operated","Mounting mode":"Fixed","lifecycle_stage":"current","Range of product":"EasyPact NW","Device short name":"XF","Device application":"Control","Control signal type":"Maintained","Supply holding power":"4.5 W 4.5 VA","Voltage release type":"Closing coil","Product or component type":"Closing coil","[Uc] control circuit voltage":"48/60 V DC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5960a1d48cfd84aaff043eba7e346838.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW21526/coil-mx-xf-mch-48-60-vdc-easypact-nw-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW21526/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage for ENW21526?","answer":"The control circuit voltage is 48/60 V DC — a dual-range coil that operates on either 48 VDC or 60 VDC without modification."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW21526","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW21526 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}