{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW21545","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW21545","canonicalUrl":"https://aoctrl.com/schneider/ENW21545","factsUrl":"https://aoctrl.com/api/mcp/products/ENW21545","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW21545 coil, electrically operated, 100/125 V DC, fixed mounting, for MX/XF/MCH releases.","salesMarkdown":"## EasyPact NW coil for MX/XF/MCH releases The Schneider Electric ENW21545 is a fixed-mount coil for the EasyPact NW range, designed to drive MX shunt trip, XF closing, or MCH undervoltage releases on NW-frame air circuit breakers and switch-disconnectors. Control voltage is 100/125 V DC, maintained signal type, electrically operated — so it holds the release in the commanded state as long as the DC control voltage is present. ## What the control voltage means for fit 100/125 V DC is a common station-battery voltage in industrial and utility switchgear — the coil is sized for that nominal range. The maintained control signal type means the coil stays energised to hold the release in its operated position; remove the DC signal and the release resets.","metaTitle":"Schneider Electric ENW21545 EasyPact NW Coil, 100/125 V DC","metaDescription":"ENW21545 is an active EasyPact NW coil for MX/XF/MCH releases, 100/125 V DC, electrically operated, fixed mounting. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Range":"EasyPact","Control type":"Electrically operated","Mounting mode":"Fixed","lifecycle_stage":"current","Range of product":"EasyPact NW","Device application":"Control","Control signal type":"Maintained","[Uc] control circuit voltage":"100/125 V DC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5bee3357fcb01ca0b051e96d02094054.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW21545/coil-easypact-nw-mx-xf-mch-100-125vdc-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW21545/alternatives.json"},"ai":{"faq":[{"question":"What control voltage does ENW21545 use?","answer":"ENW21545 is rated for 100/125 V DC control voltage, maintained signal type, electrically operated. It is designed for DC control buses in the 100–125 V range, typical of station battery systems."},{"question":"What is ENW21545 used for?","answer":"ENW21545 is a coil for EasyPact NW air circuit breakers and switch-disconnectors, driving MX shunt trip, XF closing, or MCH undervoltage releases. It mounts fixed inside the breaker mechanism."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW21545","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW21545 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}