{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24102","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24102","canonicalUrl":"https://aoctrl.com/schneider/ENW24102","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24102","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24102, 3P, 1000 A at 40 °C, 50 kA Icu at 440 V AC, drawout mounting, IP40.","salesMarkdown":"## What this 1000 A drawout breaker is for It carries a 50 kA Icu breaking capacity at 440 V AC and 42 kA at 690 V AC, both per IEC 60947-2 — that means it clears faults at those levels without the arc re-striking, which is what you need for main or feeder protection in a plant where fault currents can hit that range. Drawout mounting lets you rack the breaker out for maintenance without disconnecting power cables, a standard feature for switchgear where uptime matters. The IP40 enclosure keeps tools and fingers out but doesn't seal against water — mount it in a cabinet. Drawout mounting on rails, rear-connected at 115 mm pitch without spreader. Dimensions are 441 mm wide by 439 mm high by 395 mm deep — that's a substantial footprint, so check the switchgear cell size before committing. The control is push-button operated with a contact position indicator. Mechanical durability is 20,000 cycles with maintenance, 10,000 without — for a main breaker that's cycled infrequently, that's plenty; for a frequently switched load, consider the electrical durability: 6,000 cycles at 440 V, 4,000 at 690 V without maintenance.","metaTitle":"Schneider Electric ENW24102 EasyPact NW Circuit Breaker, 100","metaDescription":"Schneider Electric ENW24102 EasyPact NW circuit breaker, 1000 A rated current at 40 °C, 50 kA breaking capacity at 440 V AC, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"395 mm","Width":"441 mm","Height":"439 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Distribution","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm without spreader","Pollution Degree":"4 conforming to IEC 60664-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Utilization Category":"Category B","Mechanical Life Cycles":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/771e429a4db77de66725d76b96309807.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24102/circuit-breaker-frame-adapt-easypact-nw-3-poles-1000a-n-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24102/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24102","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24102 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}