{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24114","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24114","canonicalUrl":"https://aoctrl.com/schneider/ENW24114","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24114","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW24114, 3-pole circuit breaker, 2500 A at 40 °C, 50 kA Icu at 440 V AC, fixed mount, rear connection.","salesMarkdown":"The ENW24114 is a 3-pole EasyPact NW circuit breaker rated 2500 A at 40 °C, built for distribution duty in industrial switchboards. The Ics (service breaking capacity) matches the Icu at both voltage levels, so the breaker can reclose after a fault at full rating without derating. Mounting is fixed to a base plate with rear connections; the 115 mm connection pitch without spreader matches standard busbar layouts. IP40 enclosure protection keeps tools and fingers out but expects a panel door for washdown areas. The 25 ms maximum breaking time and 70 ms closing response give you the timing window for coordination with downstream breakers. Designed and tested to IEC 60947-2 for circuit breakers. Rated impulse withstand voltage of 12 kV covers typical surge environments in industrial power distribution. Mechanical durability: 20,000 cycles with maintenance, 10,000 without — figures that inform your PM schedule.","metaTitle":"Schneider Electric ENW24114 EasyPact NW Circuit Breaker, 250","metaDescription":"Schneider Electric ENW24114 EasyPact NW circuit breaker, 2500 A rated at 40 °C, 50 kA breaking capacity at 440 V AC. IEC 60947-2, 3-pole, fixed mount. Available to order — request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"422 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW25N","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"2500 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2500 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/157f2b568a5c5b48b35e13b35ca00f0f.pdf","sourceUrl":"https://www.se.com/eg/en/product/ENW24114/circuit-breaker-frame-adapt-easypact-nw-3-poles-2500a-n-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24114/alternatives.json"},"ai":{"faq":[{"question":"Who supplies ENW24114 and how is it quoted for volume purchases?","answer":"The ENW24114 is sourced through independent distribution channels. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time."},{"question":"What is ENW24114's listed depth (297 mm) on this component line?","answer":"The ENW24114 has a depth of 297 mm, with a width of 422 mm and height of 352 mm. These dimensions fit standard switchgear cubicle depths."},{"question":"What compliance documentation does this brand provide for ENW24114?","answer":"The ENW24114 is designed to IEC 60947-2 and carries a suitability-for-isolation declaration per that standard. It also meets pollution degree 4 per IEC 60664-1. For specific RoHS/REACH/UL declarations, request the manufacturer's compliance certificate with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24114","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24114 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}