{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24115","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24115","canonicalUrl":"https://aoctrl.com/schneider/ENW24115","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24115","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, air circuit breaker, ENW24115, 3-pole, 3200 A at 40 °C, 50 kA Icu at 440 V AC, IP40.","salesMarkdown":"## What the 3200 A and 50 kA ratings mean for your distribution board The 42 kA Icu at 690 V AC covers higher-voltage installations. Both Icu and Ics (service breaking capacity) are identical at those voltages, so you get full rated breaking on every fault, not a derated service rating. The IP40 enclosure keeps out tools and wires larger than 1 mm, but it is not sealed against water; install it in a clean, dry panel. ## Mechanical and electrical endurance — what to expect in service Electrical durability (Category B) is 5,000 cycles at 440 V AC and 2,500 cycles at 690 V AC without maintenance, per IEC 60947-2. If your application cycles the breaker daily (e.g., generator paralleling or furnace switching), you will hit the maintenance interval faster than a breaker that operates a few times a year. Plan for contact inspection and lubrication at the 5,000-cycle mark. Maximum breaking time is 25 ms, and maximum closing response time is 70 ms — fast enough for most distribution networks, but if you need arc-flash mitigation with zone-selective interlocking, verify the trip unit coordination with your upstream relay settings.","metaTitle":"Schneider Electric ENW24115 EasyPact NW Circuit Breaker, 320","metaDescription":"ENW24115 EasyPact NW air circuit breaker, 3200 A at 40 °C, 50 kA Icu at 440 V, IEC 60947-2, 3-pole, IP40. Currently in production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"422 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW32N","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3b39c7a765c11707056e50c59ff7f943.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24115/circuit-breaker-frame-adapt-easypact-nw-3-poles-3200a-n-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24115/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW24115?","answer":"Submit an RFQ through this listing. We source the ENW24115 to order against an RFQ, and availability with current pricing is confirmed at quote time — no stock figures on the page."},{"question":"What is ENW24115's listed depth?","answer":"The ENW24115 has a listed depth of 297 mm."},{"question":"What is ENW24115's listed range?","answer":"The ENW24115 belongs to the EasyPact NW range."},{"question":"What compliance documentation does Schneider provide for ENW24115?","answer":"The ENW24115 is certified to IEC 60947-2. It carries a pollution degree 4 rating per IEC 60664-1. For specific RoHS, REACH, or UL documentation, refer to the manufacturer's declaration available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24115","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24115 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}