{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24117","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24117","canonicalUrl":"https://aoctrl.com/schneider/ENW24117","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24117","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, air circuit breaker, ENW24117, 800 A at 40 °C, 4-pole drawout, 50 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW24117 is an EasyPact NW air circuit breaker rated 800 A at 40 °C, four-pole (4P 4d), with a drawout mounting that lets you rack the breaker out for maintenance without pulling the main bus. It's built to IEC 60947-2, the standard for low-voltage switchgear, and carries a 50 kA Icu at 220...440 V AC (42 kA at 690 V AC) — so it handles hard faults on a distribution board without welding its contacts shut. The 1000 V rated insulation voltage and pollution degree 4 rating mean it's comfortable in industrial environments where dust and humidity are part of the landscape. This breaker is a Category B device, which means it's designed for selective coordination — it can hold through a downstream short-time delay so the fault clears closer to the load, keeping the rest of the plant live. Mechanical durability is 20,000 cycles with maintenance (10,000 without), and electrical durability runs 6,000 cycles at 440 V AC without maintenance. That's a solid lifespan for a main or feeder breaker in a factory distribution panel. The ENW24117 mounts on a rail in a drawout cradle, so it's sized for a switchboard lineup — you don't bolt it direct to a panel backplate. Its footprint is 556 mm wide by 439 mm high by 395 mm deep, and connections are rear-mounted, horizontal or vertical, with a 115 mm pitch without spreader. Neutral sits on the left, and the neutral protection setting is configurable: no protection (3D), 0.5 x Ir (3D + N/2), or 1 x Ir (4D) — something to flag when you're ordering to match an existing setup. The 25 ms maximum breaking time tells you the arc is quenched fast enough to limit thermal damage in the bus bars.","metaTitle":"Schneider Electric ENW24117 EasyPact NW Circuit Breaker, 800","metaDescription":"Schneider Electric ENW24117 EasyPact NW air circuit breaker, 800 A rated, 50 kA Icu at 440 V, 4-pole drawout. IEC 60947-2. Available to order — request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW08N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"800 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"800 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ccdb83683f262203a5b160482ee7e34a.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24117/circuit-breaker-frame-adapt-easypact-nw-4-poles-800a-n-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24117/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the ENW24117?","answer":"The ENW24117 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of the ENW24117?","answer":"The ENW24117 is rated 800 A at 40 °C, with a 50 kA Icu at 220...440 V AC (42 kA at 690 V AC), 1000 V rated insulation voltage, and 4-pole drawout construction, all conforming to IEC 60947-2."},{"question":"What is the ENW24117's depth?","answer":"The ENW24117 has a depth of 395 mm."},{"question":"What range does the ENW24117 belong to?","answer":"The ENW24117 is part of the Schneider Electric EasyPact NW range of air circuit breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24117","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24117 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}