{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24120","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24120","canonicalUrl":"https://aoctrl.com/schneider/ENW24120","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24120","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW24120, 4-pole drawout circuit breaker, 1600 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The ENW24120 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1600 A at 40 °C — sized for main incoming or large feeder protection in low-voltage distribution. Its 50 kA Icu at 220…440 V AC (42 kA at 690 V) means it can safely interrupt fault currents up to that level without upstream cascading, per IEC 60947-2. The drawout mounting lets you rack the breaker out for maintenance or replacement without disturbing the bus connections — a standard feature for switchgear where uptime matters. Drawout mounting on a rail, rear-connected, with a 115 mm connection pitch without spreader. Neutral position is left; the breaker ships with a push-button control type. Physical footprint: 556 mm wide × 439 mm tall × 395 mm deep — verify your cell dimensions before racking.","metaTitle":"Schneider Electric ENW24120 EasyPact NW Circuit Breaker, 160","metaDescription":"Schneider Electric ENW24120 EasyPact NW circuit breaker, 1600 A rated current at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2. Available to order — request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW16N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"1600 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"1600 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a041a94142d7c2e4ca55d6f9a4f545ad.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24120/circuit-breaker-frame-adapt-easypact-nw-4-poles-1600a-n-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24120/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW24120?","answer":"We source this part to order against an RFQ through independent distribution; submit a request and we will confirm availability and pricing at quote time."},{"question":"What compliance documentation does ENW24120 carry?","answer":"The breaker is certified to IEC 60947-2 and carries a pollution degree 4 rating per IEC 60664-1, suitable for harsh indoor environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24120","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24120 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}