{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24130","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24130","canonicalUrl":"https://aoctrl.com/schneider/ENW24130","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24130","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24130, 2500 A at 40 °C, 50 kA Icu at 440 V AC, 4P, IP40, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW24130 is a fixed-mount, 4-pole EasyPact NW circuit breaker rated 2500 A at 40 °C with a breaking capacity of 50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches the Icu at those voltages, so after clearing a fault at rated Ics the breaker remains functional, not just safe; that matters for processes where a fault can't mean a line-down replacement. The 4P 4d protected poles with left-side neutral suit a 4-wire + ground system where the neutral is switched and protected. Electrical durability at 440 V is 5,000 cycles without maintenance — that's the number to watch for a breaker that sees frequent switching (e.g., capacitor bank or large motor feeder). If your application cycles more than that per year, consider a contactor in series for the switching duty and let the breaker serve as backup protection only. Fixed mounting on a base plate, rear connection with a pitch of 115 mm without spreader. The 537 mm width, 352 mm height, 297 mm depth define the footprint for panel layout — this is a substantial frame, not a DIN-rail device. Vertical or horizontal connection orientation gives flexibility for busbar routing.","metaTitle":"Schneider Electric ENW24130 EasyPact NW Circuit Breaker, 250","metaDescription":"Schneider Electric ENW24130 EasyPact NW circuit breaker, 2500 A rated current at 40 °C, 50 kA Icu at 440 V AC. IEC 60947-2, 4P, IP40. Current lifecycle stage, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW25N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"2500 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2500 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43785cb1e4fadeacdbddeb19bcb10488.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24130/circuit-breaker-frame-adapt-easypact-nw-4-poles-2500a-n-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24130/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24130 and how do I get a price?","answer":"The ENW24130 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest alternative to ENW24130 in the EasyPact NW family?","answer":"Within the EasyPact NW range, the closest sibling is the ENW24130 itself — the ENW25N device short name identifies the 2500 A frame. A lower-current variant (e.g., 2000 A) or higher (3200 A) would require a different frame size and different busbar connections; there is no pin-compatible drop-in substitute at a different rating."},{"question":"What compliance documentation does Schneider provide for ENW24130?","answer":"The breaker is designed to IEC 60947-2 and carries an IP40 protection rating. Suitability for isolation is confirmed per IEC 60947-2. Standard Schneider documentation includes a declaration of conformity to the Low Voltage Directive; specific RoHS/REACH declarations are available from Schneider's product documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24130","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24130 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}