{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24131","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24131","canonicalUrl":"https://aoctrl.com/schneider/ENW24131","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24131","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW24131, air circuit breaker, 3200 A, 4P, 50 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"## 3200 A air circuit breaker for distribution The Schneider Electric ENW24131 is a 4-pole air circuit breaker from the EasyPact NW range, rated 3200 A at 40 °C and built for distribution duty per IEC 60947-2. The 42 kA Icu at 690 V AC covers the higher-voltage end of industrial networks. Both the ultimate (Icu) and service (Ics) breaking capacities are the same figure at each voltage — 50 kA Ics at 440 V, 42 kA Ics at 690 V — so the breaker clears its full rated fault without derating for repetitive duty. The IP40 enclosure keeps tools and fingers out but is not washdown-rated; mount it in a cabinet if the environment is wet. Electrical durability at 440 V is 5,000 cycles without maintenance — enough for a main breaker that operates infrequently, not a switching device cycling every minute. The 25 ms maximum breaking time means the arc is quenched and the fault cleared in under three line cycles at 50 Hz. Fixed-mount design on a base plate, rear-connected. The 537 mm width, 352 mm height, and 297 mm depth define the footprint for panel layout — account for the 115 mm connection pitch without spreader when positioning busbars. Neutral is on the left. The push-button control interface means no motor operator is built in; remote closing requires an optional add-on.","metaTitle":"Schneider Electric ENW24131 EasyPact NW Circuit Breaker, 320","metaDescription":"Schneider Electric ENW24131 EasyPact NW air circuit breaker, 3200 A rated at 40 °C, 50 kA Icu at 440 V, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW32N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8ea44918e687779ec71022a1b83998ba.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24131/circuit-breaker-frame-adapt-easypact-nw-4-poles-3200a-n-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24131/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the ENW24131?","answer":"Rated 3200 A at 40 °C, 50 kA Icu/Ics at 440 V AC, 42 kA Icu/Ics at 690 V AC, 1000 V insulation voltage, 4 poles, IP40 enclosure, and compliant with IEC 60947-2."},{"question":"Where can I buy the ENW24131?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for the ENW24131?","answer":"The breaker is certified to IEC 60947-2 and carries a suitability-for-isolation marking per that standard. Pollution degree 4 per IEC 60664-1 is declared. Specific RoHS/REACH/UL declarations are available on request from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24131","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24131 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}