{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24132","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24132","canonicalUrl":"https://aoctrl.com/schneider/ENW24132","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24132","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24132 4P fixed circuit breaker, 4000 A rated current at 40 °C, 55 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW24132 is a 4-pole EasyPact NW fixed-mount circuit breaker rated 4000 A at 40 °C, with a breaking capacity of 55 kA Icu at 220–440 V AC and 42 kA Icu at 690 V AC per IEC 60947-2. The 4000 A CT rating matches the main bus for high-current distribution panels — this is a main breaker, not a feeder or branch device. The 4000 A rated current at 40 °C ambient is the continuous load it carries without tripping — size your upstream transformer and bus bars for at least this. The IP40 enclosure keeps out tools and wires over 1 mm but is not washdown-rated; install in a dry, lockable enclosure.","metaTitle":"Schneider Electric ENW24132 EasyPact NW Circuit Breaker, 400","metaDescription":"ENW24132 EasyPact NW 4P circuit breaker, 4000 A rated at 40 °C, 55 kA Icu at 440 V. IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","Product weight":"50 kg","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"55 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW40N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"4000 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"4000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2 121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9a82ea8e4e35f6cff43cbdbeddae27a7.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24132/circuit-breaker-frame-adapt-easypact-nw-4-poles-4000a-n-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24132/alternatives.json"},"ai":{"faq":[{"question":"What standards does ENW24132 comply with?","answer":"It complies with IEC 60947-2 for circuit-breaker performance, with suitability for isolation and pollution degree 4 per IEC 60664-1."},{"question":"Where can I buy ENW24132 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What is the mechanical durability of ENW24132?","answer":"20,000 cycles with maintenance and 10,000 cycles without maintenance, per IEC 60947-2. Electrical durability is 5,000 cycles at 440 V and 2,500 cycles at 690 V without maintenance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24132","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24132 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}