{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24152","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24152","canonicalUrl":"https://aoctrl.com/schneider/ENW24152","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24152","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24152, 1600 A at 40 °C, 66 kA Icu at 440 V AC, 4P, drawout, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW24152 is a 4-pole EasyPact NW drawout circuit breaker rated 1600 A at 40 °C, built to IEC 60947-2 for distribution duty. The drawout cradle lets you rack the breaker out for safe maintenance or swap without disturbing the bus connections, which cuts downtime on a line-down event. ## Breaking capacity and duty The H breaking-capacity code means this unit is the high-interrupting version of the EasyPact NW frame. At 440 V the Icu is 66 kA; the Ics (service breaking capacity) is 65 kA — 98% of Icu, so it can reclose after a fault at nearly full rating without derating the next interruption. At 690 V both Icu and Ics drop to 50 kA, still adequate for most 690 V distribution. Category B utilization means the breaker is designed for selectivity with downstream devices: it withstands a let-through current without tripping, so only the faulted branch opens. Drawout mounting on a rail support with rear connection. The 115 mm connection pitch without spreader sets the bus-bar drilling pattern. Neutral position is left. ## Durability and service life Electrical durability at 440 V is 6,000 cycles without maintenance, dropping to 4,000 at 690 V. Maximum breaking time is 25 ms; maximum closing response time is 70 ms. These numbers govern the maintenance interval: plan an inspection after 10,000 mechanical operations or 4,000 full-load breaks at 690 V, whichever comes first.","metaTitle":"Schneider Electric ENW24152 EasyPact NW Circuit Breaker, 160","metaDescription":"Schneider Electric ENW24152 EasyPact NW circuit breaker, 1600 A rated current at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW16H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"1600 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"1600 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2a5e28979b07cd8752e18773b7bd8125.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24152/circuit-breaker-frame-adapt-easypact-nw-4-poles-1600a-h-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24152/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24152 and how do I get a price?","answer":"The ENW24152 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of the ENW24152?","answer":"Rated 1600 A at 40 °C, 66 kA Icu at 440 V AC, 690 V operational voltage, 4 poles, drawout mounting, IEC 60947-2."},{"question":"What compliance documentation does the ENW24152 meet?","answer":"The ENW24152 is certified to IEC 60947-2 and is suitable for isolation per that standard. Pollution degree 4 per IEC 60664-1 covers harsh environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24152","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24152 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}