{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24153","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24153","canonicalUrl":"https://aoctrl.com/schneider/ENW24153","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24153","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24153, 2000 A at 40 °C, 66 kA Icu at 440 V AC, 4P, drawout mount.","salesMarkdown":"The Schneider Electric ENW24153 is an EasyPact NW drawout circuit breaker rated 2000 A at 40 °C with a breaking capacity of 66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC — both conforming to IEC 60947-2. ## Drawout mounting and panel integration The ENW24153 uses a drawout mounting mechanism on a rail, which means the breaker chassis stays wired to the bus while the moving portion can be racked out for maintenance or replacement without de-energizing the entire switchboard — a standard practice for high-current distribution where downtime costs are high. The 4-pole configuration with neutral on the left and rear connection positions suits fixed-pattern switchgear layouts where busbar runs are pre-drilled. ## Electrical durability and duty cycle Rated for Category B utilization, the ENW24153 delivers 6000 electrical cycles at 440 V without maintenance and 4000 cycles at 690 V. Mechanical durability is 20000 cycles with maintenance, 10000 without. The 25 ms maximum breaking time and 70 ms maximum closing response are fast enough for most distribution protection schemes, but if you need arc-flash mitigation below those thresholds, verify coordination with your upstream relay settings. ## Insulation and environmental limits Rated insulation voltage (Ui) is 1000 V AC, and operational voltage (Ue) is 690 V AC — both at 50/60 Hz. Storage temperature range is -40...85 °C without the control unit, -25...85 °C with it; operating range is -5...60 °C.","metaTitle":"Schneider Electric ENW24153 EasyPact NW Circuit Breaker, 200","metaDescription":"Schneider Electric ENW24153 EasyPact NW circuit breaker, 2000 A rated at 40 °C, 66 kA Icu at 440 V AC. IEC 60947-2, drawout mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW20H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"2000 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Neutral protection setting":"Without protection (3D) 0.5 x Ir (3D + N/2) 1 x Ir (4D)","Protected poles description":"4P 4d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5d1994f0a031167d8ecef559dc528faf.pdf","sourceUrl":"https://www.se.com/eg/en/product/ENW24153/circuit-breaker-frame-adapt-easypact-nw-4-poles-2000a-h-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24153/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of ENW24153?","answer":"66 kA Icu at 220...440 V AC and 50 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) is 65 kA at 440 V and 50 kA at 690 V."},{"question":"Where can I buy ENW24153?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What standards does ENW24153 comply with?","answer":"IEC 60947-2 for circuit-breaker performance, and IEC 60664-1 for pollution degree 4 insulation coordination. Suitability for isolation is confirmed per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24153","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24153 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}