{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24182","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24182","canonicalUrl":"https://aoctrl.com/schneider/ENW24182","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24182","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, switch disconnector, ENW24182, 1000 A AC-23A, 4 poles, drawout, 395 mm depth.","salesMarkdown":"The Schneider Electric ENW24182 is a 4-pole switch disconnector from the EasyPact NW range, rated 1000 A in AC-23A utilisation category at 690 V AC. The drawout mounting allows the chassis to be racked out for safe maintenance without disconnecting main power cables, a feature that matters when a line-down event means a freezer starts thawing. Rated operational current is 1000 A in AC-23A at 690 V. The short-time withstand current (Icw) is 50 kA for 1 s or 25 kA for 3 s, both conforming to IEC 60947-3. This tells you the switch can hold closed through a downstream fault long enough for an upstream breaker to clear, which is the basis for selective coordination in a distribution board. Ambient operating range is -5 to 70 °C, and storage range is -40 to 85 °C, which covers cold storage and freezer anteroom conditions without issue. The switch is certified as suitable for isolation per IEC 60947-3, meaning it provides a visible-break disconnection point for safe maintenance. Rated insulation voltage (Ui) is 1000 V AC, and impulse withstand (Uimp) is 12 kV — this gives headroom for 690 V systems and handles switching surges common in large motor circuits. Electrical durability is 6000 cycles at 440 V and 4000 cycles at 690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. For a main disconnect that may be operated once a shift, this is ample; for frequent switching duty, factor in the maintenance interval.","metaTitle":"Schneider Electric ENW24182 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW24182 EasyPact NW switch disconnector, 1000 A rated operational current, 4 poles, drawout mounting, IEC 60947-3. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","title":"ENW24182","Height":"439 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 1000A, N, 4 Poles, withdrawal","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","Product weight":"85 kg","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW10N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1000 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 25 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"105 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2d154acdc2797223c5f6098f2b514f89.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24182/switch-disconnector-easypact-nw-1000a-n-4-poles-withdrawal/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW24182?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is ENW24182's rated operational current?","answer":"The rated operational current (Ie) is 1000 A in AC-23A utilisation category at 690 V AC 50/60 Hz."},{"question":"What standards does the ENW24182 comply with?","answer":"It complies with IEC 60947-3 for switch-disconnectors and IEC 60664-1 for insulation coordination at pollution degree 4."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24182","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24182 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}