{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24186","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24186","canonicalUrl":"https://aoctrl.com/schneider/ENW24186","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24186","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, switch disconnector, ENW25N, 2500 A, 4 poles, drawout, AC-23A, 690 V, IEC 60947-3.","salesMarkdown":"It's built for distribution applications where you need a visible-break isolator that can handle heavy motor or resistive loads under AC-23A utilisation — that's the category for switching motors, transformers, and mixed loads with occasional inrush. The 105 kA making capacity and 50 kA short-time withstand (1 s) tell you it's sized for high-fault-capacity panels where selectivity matters. Drawout mounting on a rail, rear-connected, with the neutral on the left. That drawout feature means the switch can be racked out for maintenance or replacement without disturbing the buswork — a real time-saver in a live panel. IP40 enclosure protection is fine for indoor switchgear but not for washdown areas.","metaTitle":"Schneider Electric ENW24186 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW24186 EasyPact NW switch disconnector, 2500A rated operational current, 4 poles, drawout mounting. IEC 60947-3. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","title":"ENW24186","Height":"439 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 2500A, N, 4 Poles, withdrawal","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW25N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 2500 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 25 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"105 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47ebb35ef96d0f30a5e65fa37e443c6d.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24186/switch-disconnector-easypact-nw-2500a-n-4-poles-withdrawal/"},"ai":{"faq":[{"question":"What is the rated operational current of ENW24186?","answer":"2500 A in AC-23A duty at 690 V AC, 50/60 Hz, per IEC 60947-3. That's the motor-switching category, so it handles inrush without derating."},{"question":"Where can I buy ENW24186?","answer":"Sourced to order against an RFQ through our independent distribution network. Submit a request for current pricing and lead time."},{"question":"What standards does ENW24186 comply with?","answer":"IEC 60947-3 for switch-disconnectors, with a suitability-for-isolation mark. Rated insulation voltage 1000 V, impulse withstand 12 kV. Pollution degree 4 per IEC 60664-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24186","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24186 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}