{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24199","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24199","canonicalUrl":"https://aoctrl.com/schneider/ENW24199","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24199","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24199 switch disconnector, 3-pole, drawout, 1250 A AC-23A, 690 V AC, IP40.","salesMarkdown":"## What the 1250 A AC-23A rating means for the panel The ENW24199 is a 3-pole switch disconnector from the EasyPact NW family, rated 1250 A in AC-23A duty at 690 V AC. AC-23A covers switching of motor loads and other highly inductive circuits — this is the utilisation category that matters when the disconnector sits ahead of a group of motors or a transformer. The 1250 A figure is the operational current under that duty; at lower switching frequencies the thermal continuous current is the same value. Isolation is confirmed per IEC 60947-3, so it doubles as a visible-break safety disconnect for the downstream section. ## Short-circuit performance and withstand Rated short-time withstand current (Icw) is 66 kA for 1 second and 36 kA for 3 seconds, both at -5 to 70 °C ambient. Short-circuit making capacity (Icm) reaches 143 kA peak at 50/60 Hz. These numbers tell you the disconnector can hold closed through a downstream fault long enough for an upstream breaker to clear — a key coordination parameter when the panel feeds a high-fault bus. Drawout mounting on a rail, rear-connected. The 441 mm width, 439 mm height, and 395 mm depth set the cutout and swing clearance in the enclosure. Connection pitch is 115 mm without a spreader; vertical and horizontal connection positions are both supported. The ENW24199 carries an active lifecycle status. For a panel builder or MRO planner, that means no last-time-buy pressure and no forced substitute search.","metaTitle":"ENW24199 EasyPact NW Switch Disconnector, 1250A, 3P, Drawout","metaDescription":"Schneider Electric ENW24199 EasyPact NW switch disconnector, 1250 A rated operational current in AC-23A, 3-pole drawout. IEC 60947-3. Active. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"441 mm","title":"ENW24199","Height":"439 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 1250A, H, 3 Poles, withdrawal","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW12H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"HA","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1250 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"66 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 36 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"143 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e0f149dbd6d9cebdc1b9a7534a1740cf.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24199/switch-disconnector-easypact-nw-1250a-h-3-poles-withdrawal/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ENW24199?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to ENW24199 in the EasyPact NW family?","answer":"Within the same EasyPact NW range, the closest sibling differs only by breaking capacity code (H vs another suffix) or by fixed vs drawout mounting. The ENW24199 is the 1250 A, 3-pole, drawout variant with HA breaking capacity. If your panel uses a fixed-mounted disconnector, look for the fixed-mount equivalent in the same current class."},{"question":"What compliance documentation does Schneider provide for ENW24199?","answer":"The ENW24199 is designed and certified to IEC 60947-3. The standard itself covers isolation, making/breaking capacity, and endurance. For RoHS, REACH, and UL documentation, request the manufacturer's compliance declaration — it is not included in the base listing but is typically available from Schneider Electric upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24199","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24199 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}