{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24215","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24215","canonicalUrl":"https://aoctrl.com/schneider/ENW24215","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24215","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW switch disconnector, ENW24215, 1250 A AC-23A, 690 V, 4 poles, drawout, HA breaking capacity.","salesMarkdown":"The Schneider Electric ENW24215 is an EasyPact NW switch disconnector rated 1250 A in AC-23A duty at 690 V AC, 4 poles, drawout-mounted. The 1250 A AC-23A rating covers switching of mixed motor and resistive loads — AC-23A allows occasional switching of individual motors, so this disconnector handles both feeder and motor-circuit isolation in the same frame. The HA breaking capacity code corresponds to a rated short-time withstand of 66 kA for 1 s (36 kA for 3 s), giving selectivity headroom in high-fault-level switchboards. Drawout chassis with rear horizontal/vertical connection positions — the 115 mm connection pitch without spreader matches standard busbar centers in common LV switchgear lineups. Neutral on the left, 4-pole configuration. IP40 enclosure protection suits indoor panel installation; ambient operating range -5 to 70 °C covers most non-conditioned electrical rooms.","metaTitle":"Schneider Electric ENW24215 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW24215 EasyPact NW switch disconnector, 1250 A rated operational current (AC-23A), 690 V, 4 poles, drawout mounting. Active production, sourced to order. IEC 6","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","title":"ENW24215","Height":"439 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 1250A, H, 4 Poles, withdrawal","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW12H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Horizontal Vertical","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"HA","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1250 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"66 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 36 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"143 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/38ffff95c90320753980ae0a2e4a1513.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24215/switch-disconnector-easypact-nw-1250a-h-4-poles-withdrawal/"},"ai":{"faq":[{"question":"Where can I buy ENW24215 and how do I get a price?","answer":"ENW24215 is sourced and quoted to order against an RFQ through our independent distribution channel. Submit an RFQ for current availability and pricing."},{"question":"What is ENW24215's rated operational current?","answer":"1250 A in AC-23A duty at 690 V AC 50/60 Hz per IEC 60947-3."},{"question":"What standards does ENW24215 comply with?","answer":"IEC 60947-3 for switch-disconnectors, including isolation suitability and short-circuit making/breaking capacity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24215","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24215 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}