{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24221","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24221","canonicalUrl":"https://aoctrl.com/schneider/ENW24221","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24221","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24221 switch disconnector, 800 A AC-23A, 4 poles, fixed mounting, IP40, IEC 60947-3.","salesMarkdown":"The Schneider Electric ENW24221 is a 4-pole switch disconnector from the EasyPact NW series, rated 800 A in AC-23A duty at 690 V. The 1000 V rated insulation voltage (Ui) and 12 kV impulse withstand (Uimp) give it headroom for 690 V distribution systems where fault currents can spike. It's listed to IEC 60947-3, the standard for disconnect switches, and carries an isolation suitability mark — meaning when it's open, you can work downstream with confidence that the circuit is physically separated. The short-time withstand rating (Icw) is 66 kA for 1 second and 36 kA for 3 seconds, which tells you this switch can ride through a fault long enough for an upstream breaker to clear it — critical for selective coordination in a distribution panel. The making capacity (Icm) of 143 kA AC means it can close onto a bolted fault without welding its contacts shut. That's the kind of muscle you need on a main or feeder disconnect where fault levels are high. This is a fixed-mount switch disconnector, not a draw-out or plug-in unit. It bolts to a base plate, with rear connection terminals. The dimensions are 537 mm wide by 352 mm high by 297 mm deep — that's a substantial footprint, so plan your enclosure depth and gland-plate layout accordingly. Connection pitch is 115 mm without a spreader, which matters when you're laying out busbars or cable lugs.","metaTitle":"Schneider Electric ENW24221 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW24221 EasyPact NW switch disconnector, 800 A AC-23A, 4 poles, 1000 V insulation, IEC 60947-3. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","title":"ENW24221","Height":"352 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 800A, H, 4 Poles, fixed","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Left","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW08H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"HA","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 800 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"66 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 36 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"143 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d9ffc8d1c6f0b6eedb2bac66746edaec.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24221/switch-disconnector-easypact-nw-800a-h-4-poles-fixed/"},"ai":{"faq":[{"question":"What is ENW24221's rated operational current?","answer":"The ENW24221 is rated 800 A in AC-23A duty at 690 V AC."},{"question":"What standard does ENW24221 comply with?","answer":"It complies with IEC 60947-3, the standard for switch disconnectors and load-break switches."},{"question":"Where can I buy ENW24221 and what is the lead time?","answer":"The ENW24221 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24221","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24221 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}