{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24229","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24229","canonicalUrl":"https://aoctrl.com/schneider/ENW24229","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24229","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24229, 800 A, 50 kA Icu at 440 V AC, drawout, 4P, IP40.","salesMarkdown":"The Schneider Electric ENW24229 is an EasyPact NW drawout circuit breaker rated 800 A at 40 °C, with a breaking capacity of 50 kA Icu at 220–440 V AC and 42 kA at 690 V AC per IEC 60947-2. Designed for distribution applications, it provides Category B utilisation with 6000 electrical cycles at 440 V without maintenance. The 4-pole unit mounts on a rail with rear vertical or horizontal connections, and the drawout design simplifies panel maintenance and isolation. Drawout mounting on a rail with rear connections — vertical or horizontal — means this breaker slides into a cradle without disturbing the bus bars. The 115 mm connection pitch without spreader matches standard EasyPact NW panel cutouts. IP40 enclosure keeps dust out but isn't washdown-rated; install in a clean panel or switchgear cubicle. Lifecycle status is current. Rated insulation voltage 1000 V AC, impulse withstand 12 kV.","metaTitle":"Schneider Electric ENW24229 EasyPact NW Circuit Breaker, 800","metaDescription":"Schneider Electric ENW24229 EasyPact NW drawout circuit breaker, 800 A rated current, 50 kA breaking capacity at 440 V, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW08N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"800 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"800 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/45d5e0f5a5a3ae5f76569914fedea562.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24229/circuit-breaker-frame-adapt-easypact-nw-4-poles-800a-n-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24229/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of ENW24229?","answer":"50 kA Icu at 220–440 V AC and 42 kA Icu at 690 V AC, per IEC 60947-2."},{"question":"What standards does ENW24229 comply with?","answer":"It conforms to IEC 60947-2 for circuit-breaker performance and IEC 60664-1 for pollution degree 4."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24229","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24229 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}