{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24230","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24230","canonicalUrl":"https://aoctrl.com/schneider/ENW24230","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24230","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, circuit breaker, ENW24230, 1000 A at 40 °C, 4P, drawout, IEC 60947-2.","salesMarkdown":"It's built to IEC 60947-2 for distribution duty, with a breaking capacity of 50 kA Icu at 440 V AC and 42 kA at 690 V AC. The 42 kA Icu at 690 V AC covers most industrial 690 V distribution systems; the 50 kA at 440 V is the higher fault-current side. Rated service breaking capacity (Ics) matches the Icu values, so the breaker can reclose after a fault at those levels without maintenance — that's Category B utilization, per IEC 60947-2. The IP40 enclosure keeps out tools and wires larger than 1 mm, but not dust ingress; it's for indoor switchgear, not washdown areas. Drawout mounting on a rail with rear horizontal or vertical connections. The 115 mm connection pitch without spreader matches standard busbar spacing. Neutral is on the right. Mechanical durability is 20,000 cycles with maintenance, 10,000 without — plan the maintenance interval around the 10,000-cycle mark if the breaker sees frequent switching.","metaTitle":"Schneider Electric ENW24230 EasyPact NW Circuit Breaker, 100","metaDescription":"Schneider Electric ENW24230 EasyPact NW circuit breaker. 1000 A rated current, 50 kA breaking capacity at 440 V AC. IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW10N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"1000 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"1000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/17371d1d148170ed78091f347a7b9657.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24230/circuit-breaker-frame-adapt-easypact-nw-4-poles-1000a-n-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24230/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24230?","answer":"The ENW24230 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of ENW24230?","answer":"50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2."},{"question":"What standards does ENW24230 comply with?","answer":"IEC 60947-2 for circuit breakers, with a pollution degree of 4 per IEC 60664-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24230","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24230 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}