{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24233","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24233","canonicalUrl":"https://aoctrl.com/schneider/ENW24233","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24233","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24233 drawout circuit breaker, 4-pole, 2000 A rated current, 50 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"That 2000 A continuous rating governs the main feeder it can protect — sized for a large distribution board or a transformer secondary, not branch circuits. At 690 V the Icu drops to 42 kA — still high, but the derating matters if your system runs at 690 V line-to-line. The Ics (service breaking capacity) matches the Icu at both voltage levels — 50 kA at 440 V, 42 kA at 690 V. That means after clearing a fault at its full rating the breaker is still rated to carry and switch its load current; you don't automatically need to replace it after a single high-energy event. ## Drawout integration and panel fit Drawout mounting means the breaker chassis stays wired to the bus; the moving portion slides in and out for maintenance or replacement without disturbing the power connections. The rear connection position and horizontal/vertical orientation options give flexibility in switchgear layout, but the 556 mm width, 439 mm height, and 395 mm depth set the cubicle cutout — verify your existing drawout cradle dimensions before specifying. Designed to IEC 60947-2 for low-voltage switchgear and controlgear — the standard that governs air circuit breakers globally. Insulation voltage rated 1000 V AC, impulse withstand 12 kV.","metaTitle":"Schneider Electric ENW24233 EasyPact NW Circuit Breaker, 200","metaDescription":"Schneider Electric ENW24233 EasyPact NW drawout circuit breaker, 2000 A at 40 °C, 50 kA Icu at 440 V, IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW20N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"2000 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"2000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ccb7e9dbaf434bdff0e1b0d6e23ac111.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24233/circuit-breaker-frame-adapt-easypact-nw-4-poles-2000a-n-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24233/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24233 and how do I get a price?","answer":"The ENW24233 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not from a static listing."},{"question":"What is ENW24233's rated breaking capacity?","answer":"50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) matches those values, so the breaker remains functional after clearing a fault at its full rating."},{"question":"What compliance documentation does this brand provide for ENW24233?","answer":"The ENW24233 is designed to IEC 60947-2 and IEC 60664-1 (pollution degree 4,). It carries a suitability-for-isolation declaration. Standard Schneider documentation includes the IEC certificate and test reports; RoHS/REACH declarations are available on request through the RFQ process."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24233","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24233 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}