{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24235","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24235","canonicalUrl":"https://aoctrl.com/schneider/ENW24235","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24235","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW drawout circuit breaker, ENW24235, 4-pole, 3200 A rated current at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2, IP40.","salesMarkdown":"The Schneider Electric ENW24235 is a 4-pole drawout circuit breaker from the EasyPact NW series, rated 3200 A at 40 °C and designed for distribution applications per IEC 60947-2. The 42 kA Icu at 690 V AC covers the higher-voltage side of the same installation. Category B utilisation means it is certified for selectivity (discrimination) with downstream devices, so a fault on a feeder branch trips only the nearest upstream breaker, not the main — a key requirement for keeping critical processes online during a fault event. ## Deployment context: panel integration and environment Mounts on a rail in a drawout configuration — the breaker chassis slides into a fixed cradle, allowing the power compartment to be isolated for maintenance without unbolting busbars. Rear connection with a 115 mm pitch without spreader mates to standard bus risers in switchgear lineups. Pollution degree 4 per IEC 60664-1 indicates the environment may have conductive dust or heavy condensation — typical of industrial switchrooms near cement, mining, or chemical processing. The neutral position is on the right, which matters when ordering the matching busbar kit.","metaTitle":"Schneider Electric ENW24235 EasyPact NW Circuit Breaker, 320","metaDescription":"Schneider Electric ENW24235 EasyPact NW drawout circuit breaker, 3200 A rated current, 50 kA Icu at 440 V AC, IEC 60947-2. Available to order; confirm pricing and lead time via RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW32N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Horizontal Vertical","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"N","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79fb3806611648e48c39b1d05ce9ff49.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24235/circuit-breaker-frame-adapt-easypact-nw-4-poles-3200a-n-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24235/alternatives.json"},"ai":{"faq":[{"question":"Who supplies ENW24235 and how is it quoted for volume purchases?","answer":"ENW24235 is supplied through independent distribution channels. Volume purchases are quoted against an RFQ — confirm availability and current pricing at quote time."},{"question":"What is the closest pin-compatible alternative to ENW24235 in this component family?","answer":"Within the EasyPact NW series, the device short name ENW32N designates the same 3200 A frame and breaking capacity code N. No pin-compatible alternative outside this series is documented; the ENW24235 order code is the standard offering for this rating."},{"question":"What is ENW24235's listed depth (395 mm) on this component line?","answer":"The ENW24235 has a listed depth of 395 mm, which is the dimension from the front of the breaker to the rear connection plane — relevant for enclosure depth and busbar clearance."},{"question":"What is ENW24235's listed range (EasyPact) on this component line?","answer":"ENW24235 belongs to the EasyPact range, specifically the EasyPact NW series — Schneider Electric's standard offering for air circuit breakers in distribution applications up to 3200 A."},{"question":"What compliance documentation does this brand provide for ENW24235 (RoHS, REACH, UL, IEC)?","answer":"The ENW24235 is certified to IEC 60947-2 and carries a suitability-for-isolation declaration per that standard. The evidence does not list RoHS, REACH, or UL documentation; verify with the supplier at quote stage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24235","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24235 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}