{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24245","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24245","canonicalUrl":"https://aoctrl.com/schneider/ENW24245","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24245","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, drawout circuit breaker, ENW24245, 800 A, 66 kA Icu at 440 V AC, 4P, IP40.","salesMarkdown":"The Schneider Electric ENW24245 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 800 A at 40 °C and built to IEC 60947-2. It delivers a breaking capacity of 66 kA Icu at 220–440 V AC and 50 kA Icu at 690 V AC, with a corresponding service breaking capacity (Ics) of 65 kA and 50 kA respectively — so it clears faults and stays reusable after a trip at those levels. The 1000 V rated insulation voltage and 12 kV impulse withstand give it headroom for distribution panels feeding motor control centers or step-down transformers. ## Deployment context This is a drawout breaker — mounts on a rail with rear vertical/horizontal connections and a 115 mm pitch without spreader. IP40 enclosure protection suits indoor switchgear, not washdown areas. The push-button control and mechanical contact position indicator make it straightforward for panel builders wiring distribution sections. ## Durability and coordination Rated for 20,000 mechanical cycles with maintenance and 10,000 without; electrical durability is 6,000 cycles at 440 V and 4,000 at 690 V without maintenance. The 25 ms maximum break time and 70 ms closing response support selective coordination downstream. Listed as current production. No official successor has been issued — this remains the active order code for the 800 A, 66 kA, 4P drawout configuration.","metaTitle":"Schneider Electric ENW24245 EasyPact NW Circuit Breaker, 800","metaDescription":"Schneider Electric ENW24245 EasyPact NW drawout circuit breaker, 800 A rated current, 66 kA Icu at 440 V AC, IEC 60947-2. Sourced to order. Request RFQ for pricing and availability","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW08H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"800 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"800 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9af94383cdda0ee5ba3419ff260ad73d.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24245/circuit-breaker-frame-adapt-easypact-nw-4-poles-800a-h-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24245/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of ENW24245?","answer":"66 kA Icu at 220–440 V AC and 50 kA Icu at 690 V AC, per IEC 60947-2. The service breaking capacity (Ics) is 65 kA and 50 kA respectively."},{"question":"What standards does ENW24245 comply with?","answer":"It complies with IEC 60947-2, IEC 60664-1 pollution degree 4, and is suitable for isolation per IEC 60947-2."},{"question":"Where can I buy ENW24245?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24245","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24245 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}