{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24248","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24248","canonicalUrl":"https://aoctrl.com/schneider/ENW24248","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24248","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW24248, 4-pole drawout circuit breaker, 1600 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The Schneider Electric ENW24248 is a 4-pole drawout circuit breaker from the EasyPact NW range, rated 1600 A at 40 °C with a 66 kA Icu breaking capacity at 220...440 V AC 50/60 Hz per IEC 60947-2. The 65 kA Ics (service breaking capacity) at the same voltage tells you it can clear a fault and be immediately returned to service without inspection, which matters for uptime in continuous-process plants. The 12 kV impulse withstand (Uimp) confirms it handles switching surges and lightning-induced transients on exposed feeders. Pollution degree 4 per IEC 60664-1 means the creepage distances are sized for conductive dust or condensation — think cement plants or unheated switchrooms, not just clean data centers. ## Drawout mounting and panel integration Drawout mounting means the breaker chassis stays wired to the bus, and the moving portion racks out for maintenance or swap without disturbing the primary connections. Rear vertical/horizontal connection positions give flexibility for cable entry direction in the switchgear lineup. The 115 mm connection pitch without spreader is the dimension to check against your existing bus bar centers — if you're retrofitting into an older board, measure first. IP40 protection is fine for indoor switchgear; no washdown rating here, so keep it out of the hose-down zone.","metaTitle":"Schneider Electric ENW24248 EasyPact NW Circuit Breaker, 160","metaDescription":"Schneider Electric ENW24248 EasyPact NW drawout circuit breaker, 1600 A rated at 40 °C, 66 kA Icu at 440 V, IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","Height":"439 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW16H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"1600 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"1600 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a37df3ccbdfc644d3b5096718dbea46.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24248/circuit-breaker-frame-adapt-easypact-nw-4-poles-1600a-h-right-withdrawal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24248/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24248 and how is it quoted?","answer":"The ENW24248 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of ENW24248 at 690 V?","answer":"At 690 V AC 50/60 Hz, the Icu is 50 kA and the Ics is also 50 kA per IEC 60947-2."},{"question":"What compliance standards does ENW24248 meet?","answer":"It is designed to IEC 60947-2 for circuit breakers, with a rated insulation voltage of 1000 V AC and impulse withstand of 12 kV. Pollution degree 4 per IEC 60664-1 covers heavy industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24248","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24248 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}