{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24259","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24259","canonicalUrl":"https://aoctrl.com/schneider/ENW24259","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24259","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW, ENW24259, fixed-mount circuit breaker, 4P, 3200 A, 66 kA Icu at 440 V AC, IEC 60947-2.","salesMarkdown":"The ENW24259 is a fixed-mount, 4-pole circuit breaker from the EasyPact NW range, rated 3200 A at 40 °C. That current rating places it squarely in main-feed or large-distribution duty — think incoming supply for an industrial switchboard or a high-current bus tie. The 66 kA Icu at 220…440 V AC tells you it can safely interrupt a fault up to that level without rupturing; the 50 kA Icu at 690 V covers higher-voltage installations. Mounting is fixed to a base plate, with rear connections at a 115 mm pitch without spreader. The footprint is 537 mm wide × 352 mm high × 297 mm deep — plan for a substantial enclosure cut-out and adequate rear-access clearance for cable terminations. Electrical durability at 440 V is 5,000 cycles without maintenance (Category B, per IEC 60947-2). That's typical for a Category B breaker — designed for distribution, not frequent switching. Maximum breaking time is 25 ms, and the maximum closing response time is 70 ms. The breaker is suitable for isolation, with a visible contact position indicator. ## Environmental and insulation Operating temperature range is -5…60 °C; storage range is -40…85 °C without control unit, -25…85 °C with control unit.","metaTitle":"Schneider Electric ENW24259 EasyPact NW Circuit Breaker, 320","metaDescription":"Schneider Electric ENW24259 EasyPact NW circuit breaker, 3200 A rated current, 66 kA Icu at 440 V, IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Breaking capacity":"66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"ENW32H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","[In] rated current":"3200 A at 40 °C","Connection position":"Vertical Horizontal","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"3200 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bee68b947c2fbfdf18435c51dba5c13a.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24259/circuit-breaker-frame-adapt-easypact-nw-4-poles-3200a-h-right-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ENW24259/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy ENW24259 and how do I get a price?","answer":"The ENW24259 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is ENW24259's rated current and breaking capacity?","answer":"Rated current (In) is 3200 A at 40 °C. Breaking capacity (Icu) is 66 kA at 220…440 V AC and 50 kA at 690 V AC, per IEC 60947-2."},{"question":"What compliance documentation does this brand provide for ENW24259?","answer":"The breaker is certified to IEC 60947-2 and carries a pollution degree 4 rating per IEC 60664-1. It is suitable for isolation per IEC 60947-2. For RoHS, REACH, or UL documentation, check the manufacturer's compliance portal or request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24259","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24259 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}