{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24261","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24261","canonicalUrl":"https://aoctrl.com/schneider/ENW24261","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24261","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24261 switch disconnector, 800 A AC-23A, 4 poles, drawout, right neutral, IP40, 85 kg.","salesMarkdown":"## Switch disconnector for distribution, 800 A drawout The Schneider Electric ENW24261 is a 4-pole switch disconnector from the EasyPact NW range, rated 800 A in AC-23A duty at 690 V AC — meaning it handles the high inrush of motor and mixed loads, not just resistive heating. Drawout mounting lets you rack the unit out for safe isolation without disturbing the rear-connected buswork. Rated insulation voltage is 1000 V AC, and the unit is certified for isolation per IEC 60947-3, so it doubles as a visible-break disconnect for lockout/tagout. The 800 A AC-23A rating at 690 V is the heavy-duty motor-switching number — it covers frequent on-off cycles for motors, transformers, and capacitive loads. Short-time withstand current (Icw) is 50 kA for 1 second, or 25 kA for 3 seconds, which sets the upstream fuse or breaker coordination: the disconnector can ride through a fault long enough for the protective device to clear. Making capacity (Icm) is 105 kA peak, so it can close onto an existing fault without welding contacts. ## Pollution degree 4 — for harsh environments Pollution degree 4 per IEC 60664-1 means this disconnector is rated for continuous conductive pollution — dust, condensation, or light industrial grime that could form a tracking path. That's unusual for a switch disconnector; most stop at PD3. The IP40 enclosure keeps tools and fingers out but isn't sealed against water — install in a cabinet, not outdoors.","metaTitle":"Schneider Electric ENW24261 EasyPact NW Switch Disconnector,","metaDescription":"ENW24261 switch disconnector, EasyPact NW, 800A AC-23A, 4 poles, drawout. Active production. IEC 60947-3, IP40. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"395 mm","Range":"EasyPact","Width":"556 mm","title":"ENW24261","Height":"439 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 800A, N, 4 Poles, right, withdrawal","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","Product weight":"85 kg","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Rail","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW08N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Horizontal Vertical","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 800 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 25 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"105 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/309152ac08c9ca0189f5d9290a4b8009.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24261/switch-disconnector-easypact-nw-800a-n-4-poles-right-withdrawal/"},"ai":{"faq":[{"question":"What is the rated operational current of ENW24261?","answer":"The rated operational current is 800 A in AC-23A duty at 690 V AC, 50/60 Hz per IEC 60947-3."},{"question":"What is the short-time withstand current (Icw) for this disconnector?","answer":"Icw is 50 kA for 1 second, or 25 kA for 3 seconds, at ambient temperature -5 to 70 °C per IEC 60947-3."},{"question":"Can ENW24261 be used as an isolation switch?","answer":"Yes, it is suitable for isolation per IEC 60947-3, with a visible contact position indicator."},{"question":"Where can I buy ENW24261 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24261","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24261 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}