{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24276","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24276","canonicalUrl":"https://aoctrl.com/schneider/ENW24276","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24276","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW switch disconnector, ENW24276, 4000 A AC-23A, 4 poles, 690 V AC, fixed mounting, IP40.","salesMarkdown":"## 4000 A switch disconnector for distribution The Schneider Electric ENW24276 is a fixed-mount switch disconnector from the EasyPact NW range, rated for 4000 A in AC-23A duty at 690 V AC. That AC-23A utilisation category means it handles switching of mixed loads including motors, resistive, and slightly inductive circuits — the heaviest standard duty for a switch disconnector under IEC 60947-3. With a rated short-time withstand of 55 kA for 1 second and a making capacity of 121 kA peak, this part is sized for main incoming or bus-tie positions where fault levels are high and isolation integrity is non-negotiable. That tells you this switch can survive a fault current long enough for an upstream breaker to clear — critical for selective coordination in a distribution board. The 12 kV impulse withstand voltage (Uimp) confirms it meets the clearance and creepage requirements for 1000 V insulation systems. Pollution degree 4 per IEC 60664-1 means the part is rated for harsh environments with conductive dust or heavy condensation — not a clean-room switch. Electrical endurance under AC-23A is 5,000 cycles at 440 V and 2,500 cycles at 690 V. That is typical for a high-current switch disconnector — this is not a daily-operate device; it is a service-disconnect or infrequent-switching position. The IP40 enclosure keeps tools and fingers out but is not washdown-rated; install in a cabinet or switchboard. Fixed mounting on a base plate, rear connection, 4 poles with neutral on the right. The 537 mm width and 352 mm height mean it needs a generous cutout and busbar clearance — plan for at least 600 mm wide enclosure space. Connection pitch is 115 mm without spreader, so busbar drilling matches that centre distance. Horizontal or vertical connection orientation is acceptable, but rear-access only: the panel backplate must have clearance for the connection studs.","metaTitle":"Schneider Electric ENW24276 EasyPact NW Switch Disconnector,","metaDescription":"Schneider Electric ENW24276 EasyPact NW switch disconnector, 4000A AC-23A, 4 poles, 690V, IP40. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","title":"ENW24276","Height":"352 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 4000A, N, 4 Poles, right, fixed","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW40N","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Horizontal Vertical","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 4000 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"55 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 30 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"121 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57917ddcb54194f3432990b80f71a507.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24276/switch-disconnector-easypact-nw-4000a-n-4-poles-right-fixed/"},"ai":{"faq":[{"question":"What is the rated operational current of ENW24276?","answer":"The ENW24276 is rated 4000 A in AC-23A utilisation category at 690 V AC, 50/60 Hz, per IEC 60947-3."},{"question":"What standards does ENW24276 comply with?","answer":"It complies with IEC 60947-3 for switch-disconnectors, with suitability for isolation marked on the nameplate. Pollution degree 4 per IEC 60664-1 and a 12 kV impulse withstand voltage are also certified."},{"question":"Where can I buy ENW24276 and get current pricing?","answer":"The ENW24276 is sourced to order against an RFQ through the authorised Schneider Electric distribution channel. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24276","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24276 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}