{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24286","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24286","canonicalUrl":"https://aoctrl.com/schneider/ENW24286","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24286","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24286 switch disconnector, 1000 A rated operational current, AC-23A, 4 poles, right neutral, fixed mounting, 537 x 352 x 297 mm.","salesMarkdown":"The ENW24286 is a 4-pole switch disconnector in the Schneider Electric EasyPact NW range, rated for distribution duty. It carries a 1000 A rated operational current (Ie) in AC-23A utilisation category at 690 V AC 50/60 Hz — that's the heavy switching category for motor loads, inductive and resistive mixed, where making and breaking currents are high. Rated insulation voltage (Ui) is 1000 V AC, and impulse withstand (Uimp) is 12 kV, both per IEC 60947-3. ## Short-circuit and isolation performance Rated short-time withstand current (Icw) is 66 kA for 1 s or 36 kA for 3 s, and short-circuit making capacity (Icm) hits 143 kA peak at 50/60 Hz. These numbers govern selectivity coordination downstream — the disconnector holds in during a fault long enough for the downstream breaker to clear, without welding its own contacts. It's certified as suitable for isolation per IEC 60947-3, with a visible contact position indicator. That means it can serve as a lockable disconnect point for safe maintenance access — no separate isolator needed upstream. Fixed mounting on a base plate, rear connection, right-side neutral position. The 537 x 352 x 297 mm footprint needs panel layout planning — it's not a DIN-rail part. Connection pitch is 115 mm without spreader; vertical or horizontal cable entry works. IP40 enclosure protection — suitable for indoor panel installation, not washdown.","metaTitle":"Schneider Electric ENW24286 EasyPact NW Switch Disconnector,","metaDescription":"ENW24286 EasyPact NW switch disconnector, 1000A rated operational current, AC-23A utilisation, 4 poles, 690V AC, IP40. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","title":"ENW24286","Height":"352 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 1000A, H, 4 Poles, right, fixed","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW10H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Vertical Horizontal","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"HA","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 1000 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"66 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 36 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"143 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5ffb2f07e964df89ff89c3d0bf1930b.pdf","sourceUrl":"https://www.se.com/ae/en/product/ENW24286/switch-disconnector-easypact-nw-1000a-h-4-poles-right-fixed/"},"ai":{"faq":[{"question":"Where can I buy ENW24286 and how do I get a price?","answer":"The ENW24286 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is ENW24286's rated operational current and utilisation category?","answer":"The ENW24286 is rated 1000 A in AC-23A utilisation category at 690 V AC 50/60 Hz, per IEC 60947-3."},{"question":"What compliance documentation does this brand provide for ENW24286?","answer":"The ENW24286 is certified to IEC 60947-3 and IEC 60664-1 (pollution degree 4). The manufacturer provides standard compliance documentation for these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24286","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24286 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}