{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ENW24291","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ENW24291","canonicalUrl":"https://aoctrl.com/schneider/ENW24291","factsUrl":"https://aoctrl.com/api/mcp/products/ENW24291","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact NW series, ENW24291 switch disconnector, 3200 A AC-23A, 4 poles, right neutral, fixed mount, IP40.","salesMarkdown":"## Switch disconnector for high-current distribution The ENW24291 is a 4-pole switch disconnector from the EasyPact NW range, rated 3200 A in AC-23A duty at 690 V — that is the heavy motor-switching category (frequent on-off of motors and other high-inductive loads), not just resistive break. It is certified as an isolating switch per IEC 60947-3, so it provides visible-break isolation for safe maintenance lockout on the line side of a panel. Fixed base-plate mount, rear connection, with a horizontal or vertical cable-entry orientation. Neutral is on the right. The 115 mm connection pitch (without spreader) suits standard busbar or cable-lug spacing. Dimensions: 537 mm wide × 352 mm high × 297 mm deep. That depth (297 mm) is the front-to-back envelope — critical for cabinet depth planning when the switch sits on a rear-mounted busbar system.","metaTitle":"ENW24291 EasyPact NW Switch Disconnector, 3200 A, 4 Poles","metaDescription":"Active ENW24291 switch disconnector from EasyPact NW series. 3200 A AC-23A, 4 poles, IP40, IEC 60947-3. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"537 mm","title":"ENW24291","Height":"352 mm","Standards":"IEC 60947-3","Rated duty":"Continuous","description":"switch disconnector, EasyPact NW, 3200A, H, 4 Poles, right, fixed","Control type":"Push-button","Network type":"AC","Mounting mode":"Fixed","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Mounting support":"Base plate","Neutral position":"Right","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact NW","Device short name":"ENW32H","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Connection position":"Horizontal Vertical","Utilisation category":"AC-23A","Electrical durability":"AC-23A: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3 AC-23A: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3","Mechanical durability":"20000 cycles with maintenance conforming to IEC 60947-3 10000 cycles without maintenance conforming to IEC 60947-3","Breaking capacity code":"HA","Location of connection":"Rear","IP degree of protection":"IP40","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-3","[Ie] rated operational current":"AC-23A: 3200 A AC 50/60 Hz 690 V","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-3","Ambient air temperature for storage":"-40...85 °C without control unit","Ambient air temperature for operation":"-5...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-3","[Icw] rated short-time withstand current":"66 kA during 1 s conforming to IEC 60947-3 at -5...70 °C 36 kA during 3 s conforming to IEC 60947-3 at -5...70 °C","[Icm] rated short-circuit making capacity":"143 kA AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c8cecc7e8de6443d5772a34cad4c65d0.pdf","sourceUrl":"https://www.se.com/in/en/product/ENW24291/switch-disconnector-easypact-nw-3200a-h-4-poles-right-fixed/"},"ai":{"faq":[{"question":"Where can I buy ENW24291 and how do I get a price?","answer":"The ENW24291 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is ENW24291's listed depth (297 mm) on this component line?","answer":"The ENW24291 has a depth of 297 mm, which is the front-to-back dimension for cabinet depth planning."},{"question":"What is ENW24291's listed range (EasyPact) on this component line?","answer":"The ENW24291 belongs to the EasyPact NW range of switch disconnectors from Schneider Electric."},{"question":"What compliance documentation does this brand provide for ENW24291 (RoHS, REACH, UL, IEC)?","answer":"The ENW24291 is certified to IEC 60947-3 for switch-disconnector and isolation performance. It carries an IP40 degree of protection and a pollution degree 4 rating per IEC 60664-1. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ENW24291","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ENW24291 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}