{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EVS10H3MF60","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EVS10H3MF60","canonicalUrl":"https://aoctrl.com/schneider/EVS10H3MF60","factsUrl":"https://aoctrl.com/api/mcp/products/EVS10H3MF60","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EVS, molded-case circuit breaker, EVS10H3MF60, 3-pole, 1000 A, 65 kA Icu at 440 V AC, electronic trip unit.","salesMarkdown":"## What this breaker delivers The Schneider Electric EVS10H3MF60 is a 3-pole molded-case circuit breaker from the EasyPact EVS range, rated 1000 A at 40 °C and carrying a 65 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2. At 690 V the Icu drops to 50 kA — still enough for most 690 V distribution boards, but verify your fault level if you are on a high-capacity 690 V bus. The electronic trip unit — EVS Trip System6.0 — provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. Fixed-mount design with rear connection. Occupies 422 mm width × 352 mm height × 297 mm depth — factor that into your enclosure depth budget, especially if you are back-paneling with a gland plate behind it. Mounts on a rail or base plate. Connection pitch is 115 mm without a spreader; vertical or horizontal orientation is allowed. IP40 front face keeps out tools and finger probes, but the enclosure must handle the rest — this is not a washdown-rated device. ## Durability and fault indication Mechanical endurance: 20,000 cycles with maintenance, 10,000 without. Electrical endurance in Category B (distribution duty) is 5,000 cycles at 440/690 V without maintenance — this is a switchboard main or heavy feeder breaker, not a daily motor-switching device. Fault indication covers internal fault, overload, short-circuit, and earth fault — the trip unit flags the cause, so a returning technician sees what cleared the breaker without needing a separate event logger. Pollution degree 4 per IEC 60664-1 means it tolerates conductive dust and heavy condensation — suitable for industrial environments where a standard IP20 breaker might track across terminals.","metaTitle":"Schneider Electric EVS10H3MF60 EasyPact EVS Circuit Breaker,","metaDescription":"Schneider Electric EVS10H3MF60 EasyPact EVS molded-case circuit breaker. 1000 A rated current, 65 kA breaking capacity at 440 V AC. IEC 60947-2. Active production. Available to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Air Circuit Breakers"],"specifications":{"Depth":"297 mm","Range":"EasyPact","Width":"422 mm","Height":"352 mm","Standards":"IEC 60947-2","Control type":"Manually operated","Network type":"AC","Mounting mode":"Fixed","Thermal memory":"20 minutes before and after tripping","Trip unit name":"EVS Trip System6.0","Protection type":"Overload protection (long time) Instantaneous short-circuit protection Short time short-circuit protection Earth fault","lifecycle_stage":"current","Connection pitch":"115 mm without spreader","Fault indication":"Internal fault Overload Short-circuit Earth fault","Mounting support":"Rail Base plate","Pollution degree":"4 conforming to IEC 60664-1","Range of product":"EasyPact EVS","Trip unit rating":"1000 A","Breaking capacity":"65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"EVS10H","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Distribution","[In] rated current":"1000 A at 40 °C","Connection position":"Vertical Horizontal","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"Category B: 5000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2","Breaking capacity code":"H","Location of connection":"Rear","IP degree of protection":"IP40","Circuit breaker CT rating":"1000 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Protected poles description":"3P 3d","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Adjustable 9 settings","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable 5 settings","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-40...85 °C without control unit -25...85 °C with control unit","Ground-fault pick-up adjustment type":"Adjustable 9 settings","Long time pick-up adjustment type Ir":"Adjustable 9 settings","Ambient air temperature for operation":"-5...70 °C","[Ics] rated service breaking capacity":"65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"0.5...24 s at 6 x Ir","Instantaneous pick-up adjustment range":"2...15 x In Off","Short-time pick-up adjustment type Isd":"Adjustable 9 settings","[Uimp] rated impulse withstand voltage":"12 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"100...400 ms","Instantaneous pick-up adjustment type Ii":"Adjustable 9 settings","[Icw] rated short-time withstand current":"65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2","[Icm] rated short-circuit making capacity":"143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 105 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir","[Ig] ground-fault pick-up adjustment range":"0.2...1 x In","Ground-fault time delay adjustment type -tg":"Adjustable 5 settings","[Tg] Ground-Fault Time Delay Adjustment Range":"100...400 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a03418a56a70364d3c430b8b3d8c2e80.pdf","sourceUrl":"https://www.se.com/vn/en/product/EVS10H3MF60/easypact-evs-1000a-65ka-3p-mf-trip-system6-0-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EVS10H3MF60/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of EVS10H3MF60 at 690 V?","answer":"50 kA Icu at 690 V AC 50/60 Hz per IEC 60947-2."},{"question":"What protection functions does the EVS Trip System6.0 provide?","answer":"Overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection."},{"question":"Where can I buy the EVS10H3MF60 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EVS10H3MF60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EVS10H3MF60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}